High temperature type infrared radiation thermometer (2-color type) [hardware volume]
Table of Contents

Advertisement

Quick Links

INST.No.INE-555-P5
IR-CZ Series
HIGH TEMPERATURE TYPE
INFRARED RADIATION
THERMOMETER (2-color type)
[Hardware volume]
Model: IR-CZQH7
Always keep this instruction manual with the unit.
P l e a s e b e s u r e t o d e l i ve r t h i s i n s t r u c t i o n m a n u a l
wi t h t h e u n i t t o t h e e n d u s e r.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IR-CZ Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chino IR-CZ Series

  • Page 1 INST.No.INE-555-P5 IR-CZ Series HIGH TEMPERATURE TYPE INFRARED RADIATION THERMOMETER (2-color type) [Hardware volume] Model: IR-CZQH7 Always keep this instruction manual with the unit. P l e a s e b e s u r e t o d e l i ve r t h i s i n s t r u c t i o n m a n u a l...
  • Page 2: Table Of Contents

    INST.No.INE-555-P5 CONTENTS 1. Introduction........ 1 6. Installation ........ 13 1.1 Confirmation of the appearance ....2 6.1 Precautions in installation ......13 1.2 Confirmation of the model number ..... 2 6.2 Installation ..........14 1.3 Confirmation of accessories ......3 7.
  • Page 3 INST.No.INE-555-P5 11. Reference......... 23 12.3.7 Protective case (Soft type) Model : IR-ZCCS ········· 30 11.1 Emissivity table ........23 12.3.7-1 Connecter type (IR-ZCCSCZ) ······· 30 11.1.1 Emissivity table ( = 0.65µm) ·········· 23 12.3.7 -2 Terminal type (IR-ZCCST) ·········· 30 11.1.2 Emissivity table (= 0.9µm) ············...
  • Page 4: Introduction

    INST.No.INE-555-P5 1. Introduction The IR-CZ series is a high temperature type infrared radiation thermometer (2-color type) using a hybrid element converting functions enabling digital temperature display and parameter programming are built-in. The thermometer is focusable and has long-distance factor for free installation. The response time is 20ms suitable to on-line measurement.
  • Page 5: Confirmation Of The Appearance

    INST.No.INE-555-P5 ◆Confirmation after the packing box opening a letter Please confirm the following before use after opening a letter with this product by all means. Please contact purchase or our nearest office by any chance if there are doubts. 1.1 Confirmation of the appearance In the appearance, please confirm that a product does not have damage.
  • Page 6: Confirmation Of Accessories

    INST.No.INE-555-P5 1.3 Confirmation of accessories Because it is attached the following accessories to a product, please confirm it. Article name Quantity Remarks IR-CZ Series HIGH TEMPERATURE TYPE INFRARED RADIATION 1book This book THERMOMETER (2-color type) [Hardware volume] IR-CZ Series HIGH TEMPERATURE TYPE...
  • Page 7: For Using Safely

    1. Do not store the thermometer in hot and humid places. 2. For failures of the thermometer, don’t overhaul it by yourself, and contact your sales agent of CHINO Corporation. 2.3 Symbols in this instruction manual The symbols shown below are used depending on important degrees for using the thermometer safely and avoiding unexpected situations.
  • Page 8: Important Explanation

    INST.No.INE-555-P5 2.4 Important explanation For serious accident prevention, please read and understand these contents by all means. 1) Confirmation of the power supply voltage and the connection Please confirm it about the following before supplying a power supply. The power supply voltage matches the rating voltage. Connection is right.
  • Page 9: Warning And Attention For The Security

    Don’t use the thermometer if it was broken, smoking or nasty smelling. ! These may cause fire. For such abnormal condition, turn off the power switch at once and contact your sales agent of CHINO Corporation. Laser may damage your eyes. Don’t stare into a laser beam. Make sure to !...
  • Page 10: Configuration

    INST.No.INE-555-P5 3. Configuration Instrument Setting display □ IR-CZQH7 with power supply IR-GZ Eyepiece filter IR-ZCLF Recorder Compatible attachment IR-ZCZS Using for installation to the protection case Controller Using for securing of comparability with IR-CA series Sealing window Protective case □ (Hard type) IR-ZW □□...
  • Page 11: Model Number

    INST.No.INE-555-P5 4. Model number 4.1 Model number of the main body □ IR-CZ QH 7 Series IR-CZ Series Model QH : High temperature type infrared radiation thermometer (2-color type) ・4 to 20mA DC Analog output ・RS485 Serial communication ・One point of contact output (Connector connection type only) Distance factor L/D (Measuring distance/Measuring diameter) 7 : 200 with field diaphragm ø10...
  • Page 12: Model Number Of Accessories

    INST.No.INE-555-P5 4.2 Model number of accessories Accessories Model Reference Compatible attachment IR-ZCZS Used for Protective case (Hard type, Soft type) Protective case(Hard type) IR-ZCCH CZ: Connector T: Terminal Protective case(Soft type) IR-ZCCS CZ: Connector T: Terminal Sealing window IR-ZW0 Quartz glass Water-cooling plate IR-ZCWC Air-purge hood...
  • Page 13: Names And Functions Of Component Parts

    INST.No.INE-555-P5 5. Names and functions of component parts 5.1 Overview 5.1.1 Connector connection type (Model: IR-CZQH7N) (10) (14) (11) (12) (13) Function part cover disassembly 5.1.2 Terminal connection type (Model: IR-CZQH7T) (15) -10-...
  • Page 14: Name And Function Of The Parts

    INST.No.INE-555-P5 5.1.3 Name and function of the parts Name Function (1)Cover Glass An optical glass for protecting the objective lens from scratches, smudges, etc. (2)Objective lens tube For focusing in a measuring area. This tube has the indication of distance. For indication of distance (0.5, 0.6, 0.8, 1.25mm, ∞) (3)Distance indication plate (4)Distance marker...
  • Page 15: Function Part, Digital Display Panel

    INST.No.INE-555-P5 5.2 Function part, Digital display panel (10) 5.2.1 Function part Name Function Indications (1)Entry key Used to store the selected or programmed parameter. Used to select a parameter menu in the operating mode or the (2)Select key engineering mode. (3)Up key Used to select a parameter in the parameter selection mode or to scroll numeric characters in the parameters programming mode.
  • Page 16: Installation

    INST.No.INE-555-P5 6. Installation 6.1 Precautions in installation This product IR-CZQH7□ is a precision instrument. Please install it on the occasion of setting with care to the following item. Vibration and impacts Cau tion Vibration or impacts reduces the liability of the thermometer and causes an unstable measurement by the targeting shake to a measuring surface.
  • Page 17: Installation

    INST.No.INE-555-P5 6.2 Installation Install the thermometer to a tripod, universal head, protection case, or mounting plate etc., by using screw holes for tripod (1/4-20UNC) or screw holes for installation (4-M4) at the bottom side. When you install it in the protective cases of exclusive accessories, it is necessary to install it in the protection case after having attached a compatible attachment (model: IR-ZCZS).
  • Page 18: Targeting

    INST.No.INE-555-P5 7. Targeting 7.1 Measuring distance and measuring diameter The relation of the measuring distance and the measuring diameter is defined by the distance factor as shown in the following formula. Measuring distance (mm) = Distance factor x measuring diameter (mm) Place the thermometer at the measuring distance computed by the above formula.
  • Page 19: Focusing Of Finder Type

    INST.No.INE-555-P5 7.3 Focusing of finder type Focus a measuring object by turning the objective lens tube by its distance indication plate and the distance marker. When an objective lens tube does not turn around, you should confirm a screw for objective lens tube, and please turn it after having loosened it when it closes.
  • Page 20: Connections And Wirings

    INST.No.INE-555-P5 8. Connections and wirings When connecting power to the power terminals, make sure that all mains W ar ni ng power is turned off to prevent an electric shock. 8.1 Connector connections (Model : other than IR-CZQH7N) ◆Connection of the exclusive cable (model : IR-ZCRC The connections are completed by simply connecting the connector of the cable (IR-ZCRC) to the connector placed at the rear side of the thermometer.
  • Page 21: Terminal Connections

    INST.No.INE-555-P5 8.2 Terminal connections (model : IR-CZQH7T) Connect the exclusive cable (IR-ZCRT) or a commercially available cable to the terminal board (Terminal screw size: M3) placed at the rear side of the thermometer. P+ P- S+ S- (OP+) (OP-) Current Power supply output 24V DC...
  • Page 22: Connection Example Of The Contact Output

    INST.No.INE-555-P5 ◆IR-ZZRC□□□ Cable marker Signals Remarks POWER+ Powers supply 24V DC + Allowable voltage range 22~28V DC POWER- Powers supply 24V DC - SIGNAL+ Current output 4 to 20mA DC + SIGNAL- Current output 4 to 20mA DC - RS485 SA Serial communication RS485 SA RS485 SB Serial communication RS485 SB...
  • Page 23: Operation

    INST.No.INE-555-P5 9. Operation 9.1 Self-diagnostic function This self-diagnosis function is built-in. An error No will be displayed on abnormal conditions. Output Sub display Contents Countermeasure (Note*) Abnormal ambient Use the thermometer in the Temperature. environment from 0 to 50ºC. PROM abnormal Return to factory to us.
  • Page 24: Overflow/Underflow Indication

    INST.No.INE-555-P5 9.2 Overflow/underflow indication “oFL” is displayed when the measured temperature is higher than the maximum value of measuring range + 20ºC. “uFL” is displayed when the measured temperature is lower than the minimum value of measuring range – 20℃. Overflow indication Underflow indication 9.3 Clamp indication...
  • Page 25: Maintenance And Check

    INST.No.INE-555-P5 10. Maintenance and check 10.1 Periodical checking… Check the followings periodically or if required. Lens: Check the objective lens for dust or dirty. If dirt is present, remove it with a blower for camera lens. If the dirt cannot be removed with the blower, wipe the lens gently with cotton ball soaked in alcohol.
  • Page 26: Reference

    INST.No.INE-555-P5 11. Reference The emissivity are values determined by the material of object, profile of its surface, surface roughness, oxidized or not, measuring temperature, measuring wavelength and other factors. They are represented by the thermal radiation ratio "ε" when a black body furnace at the same temperature is measured in the same wavelength band.
  • Page 27: Emissivity Table (= 0.9Μm)

    INST.No.INE-555-P5 11.1.2 Emissivity table (= 0.9µm) 11.1.3 Emissivity table (= 1.55µm) Metal Emissivity Metal Emissivity Aluminum 0.10 to 0.23 Aluminum 0.09 to 0.40 Gold 0.015 to 0.02 Chrome 0.34 to 0.80 Chrome 0.36 Cobalt 0.28 to 0.65 Cobalt 0.28 to 0.30 Copper 0.05 to 0.80 Iron...
  • Page 28: General Specifications

    INST.No.INE-555-P5 12. General Specifications 12.1 Thermometer Model IR-CZQH7□ Measuring system 2-color type Detecting element Si /InGaAs Measuring wavelength 0.9µm /1.55µm Measuring range 900to3500ºC (Single-color type : 500 to 1400ºC) Less than 1000ºC: ±5ºC 1000 to less than 1500ºC: ±0.5% of readings Accuracy ratings *1 1500 to less than 2500ºC: ±0.6% of readings More than 2500ºC: ±1% of reading...
  • Page 29: Ir-Czqh Series Outside Dimensions

    INST.No.INE-555-P5 12.2 IR-CZQH series outside dimensions 12.2.1 Connector connection type (Model : IR-CZQH7N) Depth 4 8- M4 Depth 4 Unit:mm 12.2.2 Terminal connection type (Model : IR-CZQH7T) Depth 4 8- M4 Depth 4 -26- Unit:mm...
  • Page 30: Accessories Outside Dimensions

    INST.No.INE-555-P5 12.3 Accessories outside dimensions 12.3.1 Connector type connecting cable (Model : IR-ZZRC□□□) Unit:mm 12.3.2 Terminal type connecting cable (Model : IR-ZCRT□□□) Unit:mm □□□:Cable length (m) 002 : 2m, 005 : 5m, 010 : 10m, 020 : 20m 100 : 100m 12.3.3 Compatible cable with IR-CA (Model : IR-ZZCC) Unit:mm -27-...
  • Page 31: Compatible Attachment

    INST.No.INE-555-P5 12.3.4 Compatible attachment (Model : IR-ZCZS) Compatible attachment Material : A6063 Unit:mm 12.3.5 Eyepiece filter (Model : IR-ZCLF) Unit:mm -28-...
  • Page 32: Protective Case (Hard Type)

    INST.No.INE-555-P5 12.3.6 Protective case (Hard type) Model : IR-ZCCH 12.3.6-1 Connector type (IR-ZCCHCZ) Unit:mm 12.3.6-2 Terminal type (IR-ZCCHT) 2 4 0 1 1 9 2 2 . 5 Cooling water 4 - M 8 inlet R1/4 Purge air inlet R 1/4 Electric wire penetration hardware 1 0 b...
  • Page 33: Model : Ir-Zccs

    INST.No.INE-555-P5 12.3.7 Protective case (Soft type) Model : IR-ZCCS 12.3.7-1 Connecter type (IR-ZCCSCZ) Unit:mm 12.3.7 -2 Terminal type (IR-ZCCST) Unit:mm 12.3.8 Sealing window (IR-ZW□) Unit:mm -30-...
  • Page 34: Water-Cooling Flange

    INST.No.INE-555-P5 12.3.9 Water-cooling flange (Model : IR-VSW) Unit:mm 12.3.10 Air-purge hood (Model : IR-ZCAP) Unit:mm 12.3.11 Cooling water plate (Model : IR-ZCWC) Unit:mm -31-...
  • Page 35: Flange Installation Plate

    INST.No.INE-555-P5 12.3.12 Flange installation plate (Model : IR-ZCAF) 4-φ19 4-φ10 Unit:mm 12.3.13 Simple type universal head (Model : IR-ZMS) Unit:mm -32-...
  • Page 36 32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632 Telephone:+81-3-3956-2171 Facsimile:+81-3-3956-0915 Web site http://www.chino.co.jp/...