Page 1
INST.No.INE-555-P5 IR-CZ Series HIGH TEMPERATURE TYPE INFRARED RADIATION THERMOMETER (2-color type) [Hardware volume] Model: IR-CZQH7 Always keep this instruction manual with the unit. P l e a s e b e s u r e t o d e l i ve r t h i s i n s t r u c t i o n m a n u a l...
INST.No.INE-555-P5 CONTENTS 1. Introduction........ 1 6. Installation ........ 13 1.1 Confirmation of the appearance ....2 6.1 Precautions in installation ......13 1.2 Confirmation of the model number ..... 2 6.2 Installation ..........14 1.3 Confirmation of accessories ......3 7.
INST.No.INE-555-P5 1. Introduction The IR-CZ series is a high temperature type infrared radiation thermometer (2-color type) using a hybrid element converting functions enabling digital temperature display and parameter programming are built-in. The thermometer is focusable and has long-distance factor for free installation. The response time is 20ms suitable to on-line measurement.
INST.No.INE-555-P5 ◆Confirmation after the packing box opening a letter Please confirm the following before use after opening a letter with this product by all means. Please contact purchase or our nearest office by any chance if there are doubts. 1.1 Confirmation of the appearance In the appearance, please confirm that a product does not have damage.
INST.No.INE-555-P5 1.3 Confirmation of accessories Because it is attached the following accessories to a product, please confirm it. Article name Quantity Remarks IR-CZ Series HIGH TEMPERATURE TYPE INFRARED RADIATION 1book This book THERMOMETER (2-color type) [Hardware volume] IR-CZ Series HIGH TEMPERATURE TYPE...
1. Do not store the thermometer in hot and humid places. 2. For failures of the thermometer, don’t overhaul it by yourself, and contact your sales agent of CHINO Corporation. 2.3 Symbols in this instruction manual The symbols shown below are used depending on important degrees for using the thermometer safely and avoiding unexpected situations.
INST.No.INE-555-P5 2.4 Important explanation For serious accident prevention, please read and understand these contents by all means. 1) Confirmation of the power supply voltage and the connection Please confirm it about the following before supplying a power supply. The power supply voltage matches the rating voltage. Connection is right.
Don’t use the thermometer if it was broken, smoking or nasty smelling. ! These may cause fire. For such abnormal condition, turn off the power switch at once and contact your sales agent of CHINO Corporation. Laser may damage your eyes. Don’t stare into a laser beam. Make sure to !...
INST.No.INE-555-P5 3. Configuration Instrument Setting display □ IR-CZQH7 with power supply IR-GZ Eyepiece filter IR-ZCLF Recorder Compatible attachment IR-ZCZS Using for installation to the protection case Controller Using for securing of comparability with IR-CA series Sealing window Protective case □ (Hard type) IR-ZW □□...
INST.No.INE-555-P5 4. Model number 4.1 Model number of the main body □ IR-CZ QH 7 Series IR-CZ Series Model QH : High temperature type infrared radiation thermometer (2-color type) ・4 to 20mA DC Analog output ・RS485 Serial communication ・One point of contact output (Connector connection type only) Distance factor L/D (Measuring distance/Measuring diameter) 7 : 200 with field diaphragm ø10...
INST.No.INE-555-P5 5. Names and functions of component parts 5.1 Overview 5.1.1 Connector connection type (Model: IR-CZQH7N) (10) (14) (11) (12) (13) Function part cover disassembly 5.1.2 Terminal connection type (Model: IR-CZQH7T) (15) -10-...
INST.No.INE-555-P5 5.1.3 Name and function of the parts Name Function (1)Cover Glass An optical glass for protecting the objective lens from scratches, smudges, etc. (2)Objective lens tube For focusing in a measuring area. This tube has the indication of distance. For indication of distance (0.5, 0.6, 0.8, 1.25mm, ∞) (3)Distance indication plate (4)Distance marker...
INST.No.INE-555-P5 5.2 Function part, Digital display panel (10) 5.2.1 Function part Name Function Indications (1)Entry key Used to store the selected or programmed parameter. Used to select a parameter menu in the operating mode or the (2)Select key engineering mode. (3)Up key Used to select a parameter in the parameter selection mode or to scroll numeric characters in the parameters programming mode.
INST.No.INE-555-P5 6. Installation 6.1 Precautions in installation This product IR-CZQH7□ is a precision instrument. Please install it on the occasion of setting with care to the following item. Vibration and impacts Cau tion Vibration or impacts reduces the liability of the thermometer and causes an unstable measurement by the targeting shake to a measuring surface.
INST.No.INE-555-P5 6.2 Installation Install the thermometer to a tripod, universal head, protection case, or mounting plate etc., by using screw holes for tripod (1/4-20UNC) or screw holes for installation (4-M4) at the bottom side. When you install it in the protective cases of exclusive accessories, it is necessary to install it in the protection case after having attached a compatible attachment (model: IR-ZCZS).
INST.No.INE-555-P5 7. Targeting 7.1 Measuring distance and measuring diameter The relation of the measuring distance and the measuring diameter is defined by the distance factor as shown in the following formula. Measuring distance (mm) = Distance factor x measuring diameter (mm) Place the thermometer at the measuring distance computed by the above formula.
INST.No.INE-555-P5 7.3 Focusing of finder type Focus a measuring object by turning the objective lens tube by its distance indication plate and the distance marker. When an objective lens tube does not turn around, you should confirm a screw for objective lens tube, and please turn it after having loosened it when it closes.
INST.No.INE-555-P5 8. Connections and wirings When connecting power to the power terminals, make sure that all mains W ar ni ng power is turned off to prevent an electric shock. 8.1 Connector connections (Model : other than IR-CZQH7N) ◆Connection of the exclusive cable (model : IR-ZCRC The connections are completed by simply connecting the connector of the cable (IR-ZCRC) to the connector placed at the rear side of the thermometer.
INST.No.INE-555-P5 8.2 Terminal connections (model : IR-CZQH7T) Connect the exclusive cable (IR-ZCRT) or a commercially available cable to the terminal board (Terminal screw size: M3) placed at the rear side of the thermometer. P+ P- S+ S- (OP+) (OP-) Current Power supply output 24V DC...
INST.No.INE-555-P5 ◆IR-ZZRC□□□ Cable marker Signals Remarks POWER+ Powers supply 24V DC + Allowable voltage range 22~28V DC POWER- Powers supply 24V DC - SIGNAL+ Current output 4 to 20mA DC + SIGNAL- Current output 4 to 20mA DC - RS485 SA Serial communication RS485 SA RS485 SB Serial communication RS485 SB...
INST.No.INE-555-P5 9. Operation 9.1 Self-diagnostic function This self-diagnosis function is built-in. An error No will be displayed on abnormal conditions. Output Sub display Contents Countermeasure (Note*) Abnormal ambient Use the thermometer in the Temperature. environment from 0 to 50ºC. PROM abnormal Return to factory to us.
INST.No.INE-555-P5 9.2 Overflow/underflow indication “oFL” is displayed when the measured temperature is higher than the maximum value of measuring range + 20ºC. “uFL” is displayed when the measured temperature is lower than the minimum value of measuring range – 20℃. Overflow indication Underflow indication 9.3 Clamp indication...
INST.No.INE-555-P5 10. Maintenance and check 10.1 Periodical checking… Check the followings periodically or if required. Lens: Check the objective lens for dust or dirty. If dirt is present, remove it with a blower for camera lens. If the dirt cannot be removed with the blower, wipe the lens gently with cotton ball soaked in alcohol.
INST.No.INE-555-P5 11. Reference The emissivity are values determined by the material of object, profile of its surface, surface roughness, oxidized or not, measuring temperature, measuring wavelength and other factors. They are represented by the thermal radiation ratio "ε" when a black body furnace at the same temperature is measured in the same wavelength band.
INST.No.INE-555-P5 12. General Specifications 12.1 Thermometer Model IR-CZQH7□ Measuring system 2-color type Detecting element Si /InGaAs Measuring wavelength 0.9µm /1.55µm Measuring range 900to3500ºC (Single-color type : 500 to 1400ºC) Less than 1000ºC: ±5ºC 1000 to less than 1500ºC: ±0.5% of readings Accuracy ratings *1 1500 to less than 2500ºC: ±0.6% of readings More than 2500ºC: ±1% of reading...
Need help?
Do you have a question about the IR-CZ Series and is the answer not in the manual?
Questions and answers