Advertisement

Quick Links

en
ENGLISH...............................................................5

Advertisement

Table of Contents
loading

Summary of Contents for TEXA TMD NANO 24

  • Page 1 ENGLISH...............5...
  • Page 3: Table Of Contents

    2.2.7 Noise Hazard..................9 2.2.8 High Voltage Hazard................9 2.2.9 Poisoning Hazard................10 2.3 General User and Maintenance Warnings........11 3 SPECIFIC RULES FOR THE SAFETY IN THE INSTALLATION OF TMD NANO 24................12 3.1 Glossary..................12 3.2 General Rules................12 3.3 Operator Safety................12 3.4 Safety Precautions................13 3.5 Safety during the Installation............15...
  • Page 4 8.1 Installation precautions..............23 8.2 Suggestions for Correct Installation..........24 8.3 OBD Connector Location..............24 8.4 Protection tabs removal..............25 8.5 TMD NANO 24 positioning............25 8.6 Power supply connections - Power supply cable 3903929...26 8.7 Connections for the Diagnosis .............27 8.7.1 Diagnosis cable EOBD 3900844............27 8.7.2 Diagnosis cable EOBD FMS 3902044..........28...
  • Page 5: Introduction

    TEXA S.p.A reserves the right to make any changes deemed necessary to improve the manual for any technical or marketing requirement; the company may do so at any time without prior notice.
  • Page 6: Legend Of The Symbols Used

    1 LEGEND OF THE SYMBOLS USED The symbols used in the manual are described in this chapter. Asphyxiation Risk Explosion Risk High Voltage Hazard Fire / Burn risk Poisoning Hazard Corrosive Substances Risk Noise Hazard Moving Parts Risk Crushing Risk General Risk Important information...
  • Page 7: General Safety Regulations

    2 GENERAL SAFETY REGULATIONS 2.1 Glossary Operator: qualified person responsible for installing the tool. • • Device: the purchased product. • Workplace: the place where the operator must carry out her/his work. 2.2 Operator Safety Regulations 2.2.1 General Safety Regulations The operator must be completely clear-headed and sober when using the •...
  • Page 8: Risk Of Impact And Crushing

    2.2.3 Risk of Impact and Crushing The vehicles which are undergoing A/C system recharging operations and the devices must be properly blocked during service, using the specific mechanical brakes. Safety Precautions: • Always make sure that the vehicle is in neutral gear (or that it is set in parking position in case of a vehicle equipped with automatic transmission).
  • Page 9: Fire And Explosion Hazard

    • Make sure there are no oil stains, rags, paper or other inflammable material near the muffler. Avoid splashing electrolyte on skin, eyes and clothes, as it is a corrosive and • highly toxic compound. 2.2.6 Fire and Explosion Hazard The following are potential fires and/or explosion hazards: •...
  • Page 10: Poisoning Hazard

    Safety Precautions: • Make sure the electrical system in the workplace is compliant to current national standards. Make sure the device being used is connected to ground. • • Cut off the power supply voltage before connecting or disconnecting cables. Do NOT touch the high voltage cables when the engine is on.
  • Page 11: General User And Maintenance Warnings

    2.3 General User and Maintenance Warnings When using the device or carrying out scheduled maintenance (ex.: fuse replacement) on the device, carefully follow the information provided below. Do not remove or damage the labels and the warnings on the device; do •...
  • Page 12: Specific Rules For The Safety In The Installation Of Tmd Nano 24

    Personnel in charge of installing the remote diagnostic tools is required to follow the general safety regulations and use the TMD NANO 24 tools and related accessories for their intended use only. Furthermore, they are required to carry out the maintenance as described in this manual.
  • Page 13: Safety Precautions

    The device/accessory has been manufactured so as to result electrically safe and insulated. It is nevertheless necessary to reduce the risk of electrocution. Safety Measures: Do not touch the device/accessory, the accessories and the wiring with wet • hands. • If the liquid should penetrate inside the device/accessory, immediately disconnect the power supply wiring and contact the technical assistance.
  • Page 14 The device/accessory was designed so as to be electrically safe and to work with specific power supply voltage levels. Failure to comply with the specifications related to the power supply may impair their efficiency. Safety Measures: Do not wet the device/accessory with water or other liquids. •...
  • Page 15: Safety During The Installation

    3.5 Safety during the Installation Make sure that the power supply devices (auxiliary batteries) are disconnected and that they remain so during the entire installation before proceeding with the installation itself. Make sure that none of the electric cables, wiring in general, fuel hydraulic pipes and safety pneumatic devices are damaged during the installation.
  • Page 16: Environmental Information

    4 ENVIRONMENTAL INFORMATION For information regarding the disposal of this product please see the pamphlet supplied.
  • Page 17: Operation Of The Tool's Radio Devices

    Many other products besides those built by TEXA use this technology, such as mobile phones, portable devices, Computers, printers, cameras, Pocket PCs etc. The Bluetooth, WiFi and HSUPA interfaces search for compatible electronic devices based on the radio signals they emit and establish a connection.
  • Page 18: Information Regarding Regulations

    1999/5/EC regulation. A copy of the complete Compliance Declaration can be obtained at: TEXA S.p.A., Via 1 Maggio 9, 31050 Monastier di Treviso (TV), Italy Antennas This product was designed and tested for operation with the provided...
  • Page 19: Description

    7 Description TMD NANO 24 is a device capable of acquiring data while the vehicle is running. The data is acquired through an OBD socket or through another diagnostic socket of the vehicle in which the device is installed. TMD NANO 24 is also capable of communicating via Bluetooth or through a cable with other tracking devices TEXA.
  • Page 20: Image Of The Device

    7.1 Image of the Device Fixing hole Fixing hole Bluetooth module compartment Fixing hole USB - mini USB connector FMS - FMS diagnosis connector DIAG - main diagnostic connector CAN AUX - auxiliary diagnostic connector PWR - power connector 10. Fixing hole 11.
  • Page 21: Technical Features

    7.2 Technical Features Hardware characteristics: CPU: STM32F103ZGH6TR RAM: 512 Kb external SRAM FLASH: 2 Gbit external flash memory Bluetooth T-BUS RS-232 CAN bus Interfaces: ISO 9141-2 ISO 14230 J1708 J1939 Software characteristics: Operating System: Embedded Real Time Kernel Electrical Characteristics: Power supply: direct from 8 / 32 V vehicle battery Physical Characteristics:...
  • Page 22: Installation

    5mm Drill bit for the assembling screws. • Plastic cable ties. • • Pliers for cable terminals. Square tip pliers. • A PC connected to the Internet, to program the TMD NANO 24 control unit. •...
  • Page 23: Installation Precautions

    8.1 Installation precautions The installation must be performed by qualified personnel only. TMD NANO 24 has been designed to be used on vehicles with a continuous 12 / 24 V power supply and with the chassis connected to the negative pole.
  • Page 24: Suggestions For Correct Installation

    8.2 Suggestions for Correct Installation When choosing the most suitable place to locate the device you must consider the distance between TMD NANO 24 and the possible external interface device. Consider that the coverage range of the devices equipped with Bluetooth technology inside the vehicle is about 3 metres.
  • Page 25: Protection Tabs Removal

    8.4 Protection tabs removal The TMD NANO 24 connectors are protected by plastic tabs. Before connecting the cables needed for the installation you must remove the protection tabs. Proceed as follows: 1. Use a screwdriver to fold outward the tang to be removed.
  • Page 26: Power Supply Connections - Power Supply Cable 3903929

    8.6 Power supply connections - Power supply cable 3903929 To power the TMD NANO 24 use the specific cable that has been provided (code 3903929). Use the cable with loose wires. Proceed as follows: 1. Identify the red wire (+30 VBatt.), the blue wire (15, ignition terminal) and the black wire (ground).
  • Page 27: Connections For The Diagnosis

    8.7 Connections for the Diagnosis The diagnosis cable to connect to TMD NANO 24 varies according to the vehicle it will be installed in. 8.7.1 Diagnosis cable EOBD 3900844 The Diagnosis cable EOBD 3900844 allows to connect TMD NANO 24 to the cental unit of vehicles equipped with an OBD socket.
  • Page 28: Diagnosis Cable Eobd Fms 3902044

    8.7.2 Diagnosis cable EOBD FMS 3902044 The Diagnosis cable EOBD FMS 3902044 allows the communication through CAN, KL systems and RS232 serials. Proceed as follows: Connect the cable to the FMS input or to the CAN AUX input according to the type of installation required.
  • Page 29: Diagnosis Adaptor Cable 3904487

    8.7.3 Diagnosis adaptor cable 3904487 The Diagnosi adaptor cable 3904487 allows to connect TMD NANO 24 to diagnisis cables that are specifically for the vehicle being tested. Proceed as follows: Connect the cable to the DIAG input. Connect the vehicle's specific diagnosis cable to the adaptor cable.
  • Page 30: Diagnosis Adapter Cable For Air Platforms 3904762

    8.7.4 Diagnosis Adapter cable for Air Platforms 3904762 The Diagnosis Adapter cable for Air Platforms 3904762 connects TMD NANO 24 to the diagnosis control unit if the air platforms. Proceed as follows: Connect the cable to input PWR through the 6-Pin connector. Connect the cable to input CAN AUX through the 4-Pin connector.
  • Page 31: Checking The Installation

    Connect the TMD NANO 24 power supply connector and turn the vehicle ignition key to the “ON” position. The LED located on the top cover of the TMD NANO 24 should flash. If the LED doesn't switch on, check the power feed connections again.
  • Page 32: Configuration

    9 CONFIGURATION The communication between TMD NANO 24 and the tracking device can • via Bluetooth via cable • In both cases the configuration of the communication between the two devices occurs automatically once both are powered.
  • Page 33: Use

    10 USE Trucks and light vehicles that are in compliance with the Euro IV approval for emission limits are equipped with a diagnostic connector called OBD. The OBD is a reading interface for the acquisition of all diagnostic signals of both the vehicle and the electronic devices the vehicle is equipped with. Through this interface and through the other specific diagnostic interfaces you can connect the device to the control unit and acquire the information required for the diagnosis.
  • Page 34: Blink Code

    10.2 Blink Code The LEDs on the devices flash to indicate the various states of the devices themselves, both while they are connecting to the display unit and when they are connecting to the vehicle. The BLINK CODE of the LED is indicated in the table below. DURATION STATUS GREEN...
  • Page 35: Maintenance

    11 MAINTENANCE In order to grant a correct functioning of TMD NANO 24 it is necessary to operate regular checks of the device. We remind you to carry out the tests with the utmost care, making sure you are working in total safety during all of the phases (see also General Rules for the Safety of Operators in this manual).
  • Page 36: Legal Notices

    12 LEGAL NOTICES TEXA S.p.A. Via 1 Maggio, 9 - 31050 Monastier di Treviso - ITALY Cod. Fisc. - No. of Companies' Register of Treviso - Part. IVA: 02413550266 Single member company and subject to management and co-ordination of Opera Holding S.r.l.

Table of Contents