Download Print this page
jablotron JA-60SR Quick Start Manual

jablotron JA-60SR Quick Start Manual

Wireless smoke detector

Advertisement

Available languages

Available languages

Quick Links

The JA-60SR detects smoke and wirelessly transmits this information
to a receiving unit (control panel). It also has a built in siren to warn
people in the immediate vicinity. For testing purposes the detector is
equipped with a testing button. You can also test it remotely using any
audio/video remote control.
The detector makes regular auto testing and reports its condition to
the system regularly for full supervision.

Specifications

power
battery life time
working freguency
working range
built in sensor
radiation of sensor
sensitivity
built in siren
RF immunity
blowing air immunity
working environment
enclosure
complies with ISO 12239, EN 54-7
can be operated according to ERC REC 70-03
Hereby, Jablotron Ltd., declares that this JA-60SR is in
compliance with the essential requirements and other relevant
provisions of Directive 1999/5/EC.
Original of the conformity assessment can be found at the web page
www.jablotron.cz, section Technical support.
Contents of the set: detector, 2 plastic dowels, 2 screws, 2 AA
batteries (inside the detector)
Installation
The detector should be installed on the ceiling, with the distance
from walls 0.6 m as a minimum. The detector should not be installed in
a place with poor air circulation. If you install the JA60SR in a long
corridor (9 m and more), install at least two detectors , one at each
end. A detector can cover an area of about 50 m
partitions). The detector should not be installed close to any fan,
heating/cooling vent, fluorescent lamp or air ionizer. The JA-60SR is
not suitable for places with a high concentration of paint solvents or car
exhausts (fumes). While deciding where to install the detector, keep in
consideration that detector's batteries have to be replaced from time to
time (approximately once a year).
Note: the detector can also be triggered by heavy cigarette smoke or
fumes from cooking.
JA-60SR
JA-60SR Wireless Smoke Detector
3 V - 2 x AA battery 1.5V
about 1 year
433,92 MHz
max. 100 m (open area)
ionic chamber
max. 4 kBq
÷
y = 0,4
0,7 (EN 54-7)
95dB/1m
30V / 1m
max. 12m / s
indoor use , -10 to +60°C
IP 40
3
of free space (no
• Open the cover of the detector (press it from both sides up to the
lines on the
housing.
• Attach the rear panel with the two provided screws to the desired
location. Tighten the screws firmly, being sure that the panel is not
crooked.
• Study the installation manual of the receiver unit (control panel) to
learn how to enter the enrolling mode to enroll the detector.
• Connect batteries in the detector (removing the plastic tape). The
JA-60SR will transmit an enrollment signal and its buzzer will make
a sound. From this moment the detector is ready to work.
• Attach the detector's front cover to the rear panel so that both tabs
click. Check that the detector is fixed firmly. Warning – for safety
reasons it is impossible to close the detector without the
batteries!
• Press and hold the testing button. The detector will make an alarm
sound in few seconds. If the detector is
tested after 15 minutes from the first
testing, it won't transmit alarm signal to the
central unit (only local indication).
Jumper IR ON / OFF - the internal IR remote
control testing can be disabled by this jumper.
Normal operating mode of the detector
The detector, in normal operating mode,
s
econds (indicated by a short flash of the LED) and reports its condition to
the system.
If smoke is
detected, the JA-60SR will make a "soft" warning sound at
fi
rst and if the smoke concentration does not go down in 10 seconds, it will
trigger an alarm (siren & signal to the alarm system).
After the smoke concentration drops, the detector
m
ode again. You can stop the siren by pressing the test button or using a
remote control (see bellow).
To test the detector – sw
m
ode first. Then press and hold the testing button or use any IR
remote control (TV, stereo etc.). Standing under the installed smoke
sensor aim the remote control up to the detector holding any button
pressed. The detector, at first, will generate soft beeps and within a few
seconds it should start an alarm (siren sound and control panel
triggering). Note, that different remote controls can differ in working
distance.
Battery testing and replacement
The detector checks the condition of its batteries automatically. If it is
n
ecessary to replace batteries, the detector will inform the system about
the need for new batteries and it will start to generate "soft" beeps every
minute.
Use o
nly high quality alkaline AA batteries for replacement. After
in
stallation of new batteries the detector's buzzer will make a sound to
confirm that it is ready again.
If there is no sound after th
fl
ashing, it means that the installed batteries have a low voltage and
should be changed for new ones.
Warning – for safety reasons it i
w
ithout batteries!
Note: we recommen
d to remove dust from the detector every time you
replace its batteries. Use a dry cloth or blow on it gently.
N
ote: Dispose of batteries safely depending on the type of the batteries
and local regulation. Although this product does not contain any harmful
materials we suggest you to return the product to the dealer or directly to
the producer after usage.
1 / 3
– see the picture)
performs a self testing ev
will go to stand by
itch the control panel to the user or service
e batteries are installed and the LED is
s impossible to close the detector
Pod Skalkou 33
466 01 Jablonec nad Nisou
Czech Republic
Tel.: +420 483 559 999
fax: +420 483 559 993
Internet: www.jablotron.cz
IR
OFF
ON
ery 60
MFO51600

Advertisement

loading

Summary of Contents for jablotron JA-60SR

  • Page 1: Specifications

    • Connect batteries in the detector (removing the plastic tape). The JA-60SR will transmit an enrollment signal and its buzzer will make a sound. From this moment the detector is ready to work.
  • Page 2 Splňuje požadavky ISO 12239, EN 54-7 Detektor kontroluje stav baterií a pokud se přiblíží jejich vybití, Jablotron s.r.o. tímto prohlašuje, že tento detektor JA-60SR je ve shodě se informuje ústřednu o potřebě výměny. Detektor dále funguje a na stav základními požadavky a dalšími příslušnými ustanoveními směrnice blížícího se vybití...
  • Page 3 (indikeras av en kort blixt i LED lampan) och rapporterar tillståndet till centralenheten. Om rök upptäcks, ljuder JA-60SR först en ”beep” varnings signal och om koncentrationen av rök inte minskar inom 10 sekunder, kommer brandvarnaren att gå i larmning och sända signal till larmsystemet.