HOW TO REMOVE/ATTACH PARTS
Caution
● Before removing parts, take out all the foods on the parts.
● Do not remove parts except the ones listed here.
Please contact with a Hitachi customer service centre for cleaning such parts after removing them.
● Do not remove the platinum catalysts in the Vegetable Compartments. Do not wash them with water.
A
C
D
E
F
G
H
Lift up the door pocket while tapping the left/right of its
bottom surface, and remove it.
(It is fixed a little tightly.)
Caution
Insert the door pocket fully to the end when installing it.
If it drops, it may break and cause bruise or injury.
Draw the shelf, and pull off the 2 pins on the
lower right and remove it.
How to remove
Pull out the Vacuum Case by slightly
lifting up and moving up and down.
60
BB0055761Y_R-G420KH_A.indd 60
Request
B
Slightly lift up the back
of the shelf and draw it.
Forks of the shelf (Right / Left)
Upper
shelf
Middle
shelf
When installing the shelf, slide it until it reaches to the interior wall, then slightly lift up
the back of the shelf and push it in.
(hitch the forks of the shelf to the parts on the back of the shelf)
Fixed shelf
Forks
Vacuum Case
How to attach
Insert the Vacuum Case so that both
right and left convex ribs on the case
can slide under the guide rail of the
Vacuum Container.
Lastly, hold down the handle to lock.
Request
Height adjustable upper and middle shelf
Remove the middle shelf before removing the upper shelf.
Raise the shelf,
as shown in the
drawing.
Door pocket
Height adjustable lower shelf
Slightly lift up and pull out.
Vacuum Container
Convex rib
Check if it is fixed properly by taking it in and out a few times.
Rotate and
remove it.
Tap
Tap
Guide rail
Vacuum Case
19/11/08 9:08