Burner Components - Riello RS 1200/E BIOGAS/GPL C01 FS2 Installation, Use And Maintenance Instructions

Forced draught gas burner
Table of Contents

Advertisement

3.8

Burner components

9
20050804
11
1
Lifting eyebolts
2
Fan
3
Fan motor
4
Air gate valve servomotor
5
Maximum gas pressure switch with pressure test point
6
Combustion head
7
Ignition pilot
8
Flame stability disk
9
Electric panel board - cover
10 Servomotor for gas butterlfy valve
11 Air inlet to fan
12 Manifold
13 Thermal insulation screen for securing burner to boiler
14 Gas butterfly valve
15 Shutter
16 Lever for movement of combustion head
17 Tie rods for air damper movement
18 Air pressure switch
19 Air pressure test point
20 Ignition pilot attachment
21 UV fotocell holder
22 Hinge for opening burner
23 Air pressure test point pressure test point "+"
24 Electric board protection
The burner can be opened either on the right or left
sides, irrespective of the side from which fuel is sup-
plied. When the burner is closed, the hinge can be
WARNING
re-positioned on the opposite side.
Technical description of the burner
10
1
18
6
12
7
8
14
4
15
19
13
11
GB
20
16
21
24
23
5
22
17
2
Fig. 5
20049577

Advertisement

Table of Contents
loading

Table of Contents