Slant/Fin VGH-80-CH User's Information Manual page 26

High efficiency condensing gas boiler
Table of Contents

Advertisement

Blocking
Error
code
118
WD_COMM_
ERROR
119
RETURN_
OPEN
120
SUPPLY_
OPEN
122
DHW_OPEN
123
FLUE_OPEN
125
OUTDOOR_
OPEN
126
RETURN_
SHORTED
127
SUPPLY_
SHORTED
129
DHW_
SHORTED
130
FLUE_
SHORTED
132
OUTDOOR_
SHORTED
133
NET_FREQ_
ERROR
134
RESET_BUTTO
N_ ERROR
135
PHASE_NEUTR
AL_ REVERSED
136
T_EXCHANGE_
BLOCK_ERROR
155
WD_CONFIG_
ERROR
162
FILL_WARNING
26
Description
Watchdog communication
error
Return sensor open
Supply sensor open
DHW sensor open
Flue sensor open
Outdoor sensor open
Return sensor shorted
Supply sensor shorted
DHW sensor shorted
Flue sensor shorted
Outdoor sensor shorted
Net freq. error detected by
the watchdog
Too many resets in a short
time period
Live and neutral of the
main voltage power supply
input are reversed
Exchange temperature
exceeded 194 ºF (90 ºC).
Watchdog fan configuration
setting error
Error generated directly
when pressure drops
below Minimal_Pressure.
Demand has stopped, but
no error is to be stored at
this time.
E95.1901EN032 User manual Slant Fin VGH-CH / CO
Cause
Solving
wrong
If the boiler does not start
programmed BCU
after Reset, contact your
or PB
installer
malfunctioning
If the boiler does not start
return sensor or
after Reset, contact your
not connected
installer
malfunctioning
If the boiler does not start
supply sensor or
after Reset, contact your
not connected
installer
malfunctioning
If the boiler does not start
DHW sensor or not
after Reset, contact your
connected
installer
malfunctioning flue
If the boiler does not start
sensor or not
after Reset, contact your
connected
installer
malfunctioning
If the boiler does not start
outdoor sensor or
after Reset, contact your
not connected or
installer
wrong CH-mode
programmed
malfunctioning
If the boiler does not start
return sensor or
after Reset, contact your
short circuiting
installer
malfunctioning
If the boiler does not start
supply sensor or
after Reset, contact your
short circuiting
installer
malfunctioning
If the boiler does not start
DHW sensor or
after Reset, contact your
short circuiting
installer
malfunctioning flue
If the boiler does not start
sensor or short
after Reset, contact your
circuiting
installer
malfunctioning
If the boiler does not start
outdoor sensor or
after Reset, contact your
short circuiting
installer
wrong frequency
If the boiler does not start
from power grid or
after Reset, contact your
aggregate
installer
reset too many
Wait or disconnect and
times by user or
reconnect power supply
installer
phase and neutral
If the boiler does not start
are wrongly
after Reset, contact your
connected
installer
water temperature
If the boiler does not start
is above 194 ºF
after Reset, contact your
(90 ºC).
installer
wrongly program-
If the boiler does not start
med BCU or PB
after Reset, contact your
installer
the water pressure
Refill the system until the
is below the
pressure is above 1 bar or
minimum pressure
14.5 psi
level