K&S KS 12-1E ATSR Instruction

Gasoline generators, two-cylinder gasoline generators

Advertisement

Please, read this manual
carefully before use!
GASOLINE GENERATORS
KS 12-1E ATSR
KS 12-1E 1/3 ATSR
TWO-CYLINDER
GASOLINE GENERATORS
KS 15-1E ATSR
KS 15-1E 1/3 ATSR
Instruction
ENG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KS 12-1E ATSR and is the answer not in the manual?

Questions and answers

Summary of Contents for K&S KS 12-1E ATSR

  • Page 1 Instruction Please, read this manual carefully before use! GASOLINE GENERATORS KS 12-1E ATSR KS 12-1E 1/3 ATSR TWO-CYLINDER GASOLINE GENERATORS KS 15-1E ATSR KS 15-1E 1/3 ATSR...
  • Page 2: Table Of Contents

    CONTENTS 1. Preface 2. Safety precautions 2.1. Work area 2.2. Electrical safety 2.3. Personal safety 2.4. Safety precautions for gasoline generator operation 3. Safety symbols 3.1. Description of safety symbols for battery operation 3.2. Description of safety symbols for battery operation 4.
  • Page 3: Preface

    1. PREFACE Congratulations on your purchase of the gasoline generator from Könner & Söhnen. This manual contains safety instructions, a description of the use and commissioning of Könner & Söhnen generators and procedures for their maintenance. The generator manufacturer may make some modifications that may not be reflected in this manual.
  • Page 4: Electrical Safety

    - Do not use the generator near flammable gases, liquids or dust. During operation of the generator, its exhaust system becomes very hot. This may cause fire or explosion of these materials. - Keep the work area clean and well lit to avoid injuries. - Keep unauthorized persons, children and animals away from the running generator.
  • Page 5: Safety Precautions For Gasoline Generator Operation

    WARNING - DANGER! Failure to comply with these requirements may result in fire or explosion of the generator, as well as fire in the building wiring. - Make sure there are no foreign objects on the generator when it is turned on. Use the product for its intended purpose only.
  • Page 6: Safety Symbols

    3. SAFETY SYMBOLS DESCRIPTION OF SAFETY SYMBOLS FOR GENERATOR OPERATION f. Read this owner’s manual carefully before operating the device. g. Do not touch the generator with wet or dirty hands. i. Observe fire safety regulations, do not operate the generator near open flame. j.
  • Page 7: Description Of Generator Inscriptions

    4. DESCRIPTION OF GENERATOR INSCRIPTIONS APART FROM THE SAFETY SYMBOLS, THE GENERATOR CONTAINS THE FOLLOWING INSCRIPTIONS: Specifications chart. Specifications vary from model to model. For more information, see section “Generator Specifications”. Noise level is indicated. The noise level varies with the model. For more information, see “Generator Specifications”.
  • Page 8: Overview And Components Of One-, Two-Cylinder Generator

    5. OVERVIEW AND COMPONENTS OF ONE-, TWO-CYLINDER GENERATOR Fig. 1 1. Reinforced steel frame 7.Oil filter 2. Fuel tank 8. Oil bleeder screw 3. Fuel level indicator 9. Engine 4. Control panel 10. Manual start for models KS 12-1E 5. 12 V battery ATSR, KS 12-1E 1/3 ATSR 6.
  • Page 9: Generator Delivery Package

    6. GENERATOR DELIVERY PACKAGE 1. Generator 2. Packaging 3. Owner’s manual 4. Warranty card 5. Accessories ACCESSORIES 1. 2x start keys; 2. 1x spark plug key 3. Transportation kit (wheels, support legs, handles, semi-axle) Fig. 2...
  • Page 10: Generator Specifications

    7. GENERATOR SPECIFICATIONS Model KS 12-1E ATSR KS 12-1E 1/3 ATSR KS 15-1E ATSR KS 15-1E 1/3 ATSR Voltage (V) Maximum power 9.2 kW 8.2 kW 11.5 kVА 12.5 kW 11.5 kW 15.6 kVА Nominal power 9.0 kW 8.0 kW 11.25 kVА...
  • Page 11 8. CONTROL PANEL For model KS 12-1E ATSR Fig. 3 ENGINE START 1. Start switch 7. Grounding 2. Emergency stop button 8. 32 А outlet (230 V) 3. Wyświetlać LED 9. 16 А outlet (230 V) 4. Circuit breakers 10. ATS output (universal 8-pin) 5.
  • Page 12: Control Panel

    CONTROL PANEL For model KS 15-1E ATSR Fig. 5 ENGINE START 1. Start switch 8. 32 А outlet (230 V) 2. Emergency stop button 9. 16 А outlet (230 V) 3. LED display 10. ATS output (universal 8-pin) 4. Circuit breakers 11.
  • Page 13: Digital Display

    9. DIGITAL DISPLAY To select the indicators, press the button on the display. The selection of indicators is cyclic. Fig. 7 This mode displays the generator output voltage in volts. This mode displays the generator output frequency in Hertz. This mode displays the generator operation time from start-up in minutes.
  • Page 14: Check Before Getting Started

    11. CHECK BEFORE GETTING STARTED NOTE! Be sure to carry out the following preparation before starting the generator: Fig. 8 Oil dipstick 1. Check for fuel in the tank: a) Wear protective gloves to avoid getting gasoline on your skin b) Unscrew the fuel cap and check the fuel level in the tank.
  • Page 15: Engine Start

    12. ENGINE START WARNING - DANGER! Before starting the engine make sure that the total power of tools or power consumers corresponds to the rated power of the generator. Do not exceed the nominal power of the generator. Do not connect any devices before you start the engine! NOTE! Do not use in single-phase and three-phase mode at the same time Before connecting any devices to the generator, make sure that they are in good...
  • Page 16: Connecting The Generator And Ats Unit To The Mains Supply

    13. CONNECTING THE GENERATOR AND ATS UNIT TO THE MAINS SUPPLY Diagram for connecting the generator and ATS unit to power consumers and mains supply Fig. 11 L- Phase GENERATOR SUITABLE FOR N - Neutral CONNECTING AN ATS UNIT ATS UNIT MAINS SUPPLY ELECTRIC METER...
  • Page 17: Engine Stop

    14. ENGINE STOP PLEASE NOTE! Disconnect all devices before stopping the generator! Do not stop the generator if it has any devices connected to it. This may disable the generator! TO STOP THE GASOLINE GENERATOR: 1. Disconnect all power consumers from the generator, set the circuit breaker to the “OFF”...
  • Page 18: Recommended Maintenance Schedule

    16. RECOMMENDED MAINTENANCE SCHEDULE Level check Engine oil Replacement Cleaning Air filter Replacement Cleaning Oil filter Replacement Level check Fuel tank Cleaning Cleaning Fuel filter Replacement 17.RECOMMENDED OILS Motor oil significantly affects the engine performance and is the main factor that determines its service life.
  • Page 19 REPLACING OR ADDING MOTOR OIL If the oil level drops, fresh oil must be added to ensure proper operation of the generator. Check the oil level according to the maintenance schedule. To drain oil, proceed as follows: 1. Wear protective gloves to avoid getting oil on your skin. 2.
  • Page 20: Air Filter Maintenance

    Fig. 16 shows the arrangement of the oil filter for generator models KS 12-1E ATSR, KS 12-1E 1/3ATSR Fig. 16 Oil cooler Oil filter For generator models KS 12-1E ATSR, KS 12-1E 1/3ATSR, the oil filter is located on the front of the generator below the control panel.
  • Page 21: Battery Operation

    20. BATTERY OPERATIONH The generator battery is maintenance-free. If the generator has not been used for a long time, the battery may fail. To extend battery life, it is recommended that you recharge the battery with an external charger (not included) every three months. Use protective gloves when handling the battery.
  • Page 22: Generator Storage

    22. GENERATOR STORAGE The generator must be stored in a dry, well-ventilated area that is free from dust. Keep away from children and animals. It is recommended to store and use the generator at a temperature of -20 to +40 °C. Do not expose the generator to direct sunlight and precipitation Note! We recommend that you keep the generator in good working order at all times.
  • Page 23: Troubleshooting

    24. TROUBLESHOOTING Fault Probable cause Remedy The engine start key (button) is Set the engine start key (button) set to the OFF position to the ON position The fuel valve is set to the “CLOSE” Move the fuel valve to the position “OPEN”...
  • Page 24: Average Power Consumption Of Devices

    25. AVERAGE POWER CONSUMPTION OF DEVICES Device Power (kW) Iron 500-1100 Hair dryer 450-1200 Coffee machine 800-1500 Electric cooker 800-1800 Toaster 600-1500 Heater 1000-2000 Vacuum cleaner 400-1000 Radio 50-250 Grill 1200-2300 Oven 1000-2000 Fridge 100-150 TV set 100-400 Perforator 600-1400 Drill 400-800 Freezer...
  • Page 25: Warranty Provisions

    26. WARRANTY PROVISIONS Gasoline generators are covered by an extended warranty of up to two years or 1,200 operating hours (whichever comes first) subject to paid technical service at an authorized service center one year after purchase or after 600 operating hours (whichever comes first).
  • Page 26 NOTES ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ The current list of service centers can be found on the official importer’s website: www.ks-power.de/en/...
  • Page 28 KONTAKTDATEN Deutschland: DIMAX International GmbH Deutschland, Hauptstr. 134, 51143 Köln, www.ks-power.de info@dimaxgroup.de Polska: DIMAX International Poland Sp.z o.o. Polen, Warczawska, 306B 05-082 Stare Babice, www.ks-power.pl info.pl@dimaxgroup.de Україна: ТОВ «Техно Трейд КС», вул. Електротехнічна 47, 02222, м. Київ, Україна www.ks-power.com.ua sales@ks-power.com.ua Россия: ТД...

This manual is also suitable for:

Ks 15-1e atsrKs 15-1e 1/3 atsrKs 12-1e 1/3 atsr

Table of Contents