Useful tip: If the engine stalls or does not start, turn the engine switch
to the "ON" position, and then pull the manual starter. If the oil level
indicator flickers for several seconds, add oil and restart the engine.
ISS-Systems
With more than 10 years of experience, TM Könner & Söhnen constantly
upgrades and implements the latest technologies in its products, thereby
offering demanding customers more efficient, improved systems and devices.
The experience gained over the years has been reflected in the new line of
inverter generators.
Inverter generators KS 3300i S, KS 4000iE S, KS 3300iEG S-Profi, KS 3500iE G-Profi,
KS 4000iEG S-Profi, KS 7100iE G-Profi, KS 7200iEG S-Profi are equipped with
Intelligent Start System (ISS). This system facilitates start of the generator
engine in the gasoline mode.
THE OPERATING PRINCIPLE OF THE ISS SYSTEM IS AS FOLLOWS:
When you start the generator by turning the key, the ISS system bypasses the
carburetor and triggers the post combustion fuel injection, thereby enriching the
fuel at startup.
When starting the generator for the first time (when the entire system is
completely empty), be sure to close the air choke so that the system can pump
fuel faster.
During any subsequent startups, there is no need to use the air choke.
The ISS system will quickly start the engine without much effort.
Advanced inverter generators are reliable, practical and provide high quality
electricity.
OVERLOAD INDICATOR
The overload indicator lights up when the connected generator is overloaded,
the inverter control unit overheats or the AC output voltage rises.
If the overload indicator goes on, the engine will continue to operate, but the
generator will no longer produce electricity. In this case, you must perform the
following steps:
1. Turn off all connected electrical appliances and stop the engine.
2. Reduce the total power of the connected devices until the nominal power of
the generator is reached.
3. Check if the vent grid is clogged. Remove excess dirt or debris, if any.
4. After checking, start the engine.
!
The overload indicator may light up within several seconds after
start-up or when connecting electrical devices requiring a high starting
current, such as a compressor or voltage indicator.
However, this is not a malfunction.
!
PLEASE NOTE!
!
PLEASE NOTE!
27