Kane 425 Manual page 14

Flue gas analyser
Table of Contents

Advertisement

Hold
for 2+ seconds to log a full combustion report.
AUX display
O
2
CO
15:04:11
BAT
Press
to print a full combustion test (also sends to PC if Bluetooth fitted).
Hold
for 2+ seconds to log a full combustion report.
Viewing / printing a logged combustion test
Select MENU / REPORT / COMB'N / VIEW
Hold
or
Use
and
Press
to print the test (also sends to PC if Bluetooth fitted).
NOTE:
The "AUX" display can be used to time and manually record
ambient CO levels to comply with BS7967 (see "ROOM CO" –
Section 4.5).
20.9
00
39
for 2+ seconds to select the log number to be viewed.
to scroll through the individual readings on line 2 & 3.
KANE425 manual
The default AUX (auxillary) display is
shown including Oxygen, Carbon
Monoxide, current time & battery status.
The AUX display can be customised via
MENU / SCREEN / AUX to change the
parameters on lines 1, 2, 3 and 4.
They remain the AUX parameters until
changed again by the user
Page 14