Summary of Contents for Kane 258

  • Page 1 Kane International Ltd Kane House, 11 Bessemer Road, Welwyn Garden City, Hertfordshire, AL7 1GF, UK UK: 0800 059 0800 Int: +44 (0) 1707 375550 Fax: +44 (0) 1707 393277 Email: sales@kane.co.uk KANE 258 Flue Gas Analyser with direct CO, O & CO sensor protection Stock No: MAN00100 Rev: 1.20720...
  • Page 2: Table Of Contents

    11-15 QUICK START USER INTERFACE STATUS STATUS BAR STATUS BAR LAYOUT STATUS BAR MESSAGE ZONE STATUS BAR ZONE STATUS BAR ICONS STATUS BAR MENU OPTIONS STANDARD OPTIONS USING THE MENU MENU ITEMS MEASURING FLUE GASSES 16-17 2 KANE 258 MANUAL...
  • Page 3 REPORT NAVIGATION MENU OPTIONS TEMPERATURE TESTING TEMPERATURE DISPLAY VIEWING-PRINTING PRINTOUTS SPECIFICATIONS EU DECLARATION OF CONFORMITY SERVICE – CALIBRATE - RECERTIFY 25-29 KANE ASSET MANAGER (KAM) 26-27 GUARANTEED SAME DAY DESPATCH WHERE TO SEND YOUR ANALYSER COLD WEATHER PRECAUTIONS KANE 258 MANUAL...
  • Page 4: Kane 258 Overview

    Your KANE258 stores up to 30 logs of any combination of Combustion & Temperature test results. Your KANE258 can send test readings to our optional KANE IRP-2 infrared printer or KANE’s wireless App if wireless is fitted. Two lines of 16 characters can be added to the header of the printouts.
  • Page 5: Instrument Features & Keypad

    INSTRUMENT FEATURES & KEYPAD KANE 258 MANUAL...
  • Page 6: Keypad Buttons

    Enter key-used to select the current option Navigate down-short press to scroll down Data hold - short press to hold current data on screen (see status bar section) Pump toggle - long press to toggle pump on & off 6 KANE 258 MANUAL...
  • Page 7: Instrument Layout

    Flue probe temperature T1 Flue gas inlet Watertrap drain with red plug Red connector – plugs into Flue Flue Probe Temperature Plug – Gas Inlet into T1 Narrow (+ve) pin must be on right side Flue probe hose KANE 258 MANUAL...
  • Page 8: Back Of Analyser - Probe Etc

    Magnets x2 Thermocouple Stainless steel Shaft Depth stop cone Watertrap drain with red plug Thermocouple wire Gas path 8 KANE 258 MANUAL...
  • Page 9: Batteries

    If your batteries discharge so the analyser enters a low power shutdown, 1 hour’s charge provides approx 2 hours continuous use. BATTERY DISPOSAL Always dispose of depleted batteries using approved disposal methods that protect the environment. KANE 258 MANUAL...
  • Page 10: General Safety

    Your analyser’s protective cover is fitted with strong magnets – magnetic fields can cause damage to magnetic storage media. Certain electronic devices are sensitive to magnetic fields & may be damaged permanently if exposed to a strong magnetic field. 10 KANE 258 MANUAL...
  • Page 11: First Time Use

    Your KANE258’s large display shows 5 lines of tests & a status bar. The backlight activates on each button press then turns off after 10 seconds. Navigate through your options & menu choices via the 3 dedicated & buttons. Button presses are either short or long presses. KANE 258 MANUAL...
  • Page 12: Status

    Status bar STATUS BAR The Status bar shows instrument status & offers options based on your settings. Navigate through the status bar options via the & buttons when the status bar is on the display. Status bar 12 KANE 258 MANUAL...
  • Page 13: Status Bar Layout

    Display alternates CALIBRATION DUE between calibration due WARNING MESSAGE symbol & current time Display alternates air AIR PURGE purge delay symbol & “SNOOZE” TIMER current time Display alternates LOW BATTERY between BAT symbol & WARNING MESSAGE current time KANE 258 MANUAL...
  • Page 14: Status Bar Zone

    Icons give quick & simple status information: STATUS BAR ICONS ICON LIST Pump status On or Off PUMP Analyser has logged/ LOGGED DATA stored data Data being sent to SENDING DATA App or Printer Battery Status indication BATTERY 14 KANE 258 MANUAL...
  • Page 15: Status Bar Menu Options

    Rotate dial to MENU to customise your analyser’s default settings to your requirements. Navigate through the Menu system using these buttons & Menu option to edit NOTE: To exit Menu turn your analyser’s rotary dial to any position – changes not entered are not stored. KANE 258 MANUAL...
  • Page 16: Menu Items

    – use the flue probe’s depth stop cone to set the position. With balanced flues, make sure the probe is positioned far enough into the flue so no air can “back flush” into the probe. SAFETY WARNING Ensure your flue probe handle does not get hot! 16 KANE 258 MANUAL...
  • Page 17: Printing

    PRINTING Press & release to send your test results to our optional KANE IRP-2 printer or KANE App. You can stop printing by pressing the button again. KANE INFRARED PRINTER To use your printer, switch it on & place its infrared receiver in line with the emitter on top of your analyser –...
  • Page 18: Co Protection Pump Operation

    Your analyser displays P-OFF until CO levels fall below 2000ppm. TEMPERATURE SCREEN T1 flow Temperature reading T2 return Temperature reading Differential Temperature Status bar CO/CO2 SCREEN CO/CO2 Ratio reading Carbon monoxide reading Carbon dioxide reading Excess air reading Flue gas losses Status bar 18 KANE 258 MANUAL...
  • Page 19: O2/Eff Screen

    No. of stored Temperature logs Total memory used Menu options MENU OPTIONS View stored reports if available - enter secondary menu to select report type Delete all stored reports if available – to delete long press button Return to main menu KANE 258 MANUAL...
  • Page 20: Viewing Stored Logs

    NAVIGATING STORED REPORTS Once you select your report the first report is displayed: LOG Number of that type Time & date of the LOG - alternates between both Report readings specific to report type Navigation menu options 20 KANE 258 MANUAL...
  • Page 21: Report Navigation Menu Options

    Rotate dial to TEMP & connect your K type thermocouples to T1 to measure temperature or T1 & T2 to measure differential temperature. T2 Temperature T1 Temperature TEMPERATURE DISPLAY Use T1 connection for flow temperature sensor Use T2 connection for return temperature sensor Real time temperature difference Status bar KANE 258 MANUAL...
  • Page 22: Viewing-Printing

    VIEWING/PRINTING Press the button to send your Temperature report to our optional KANE IRP-2 printer or send to KANE App if Wireless module is fitted. Press & hold the button for 2 seconds to log a temperature report. PRINTOUTS Combustion...
  • Page 23: Specifications

    Parts 1-3 in accordance to 1st German Federal Emission Control Ordinance (Bim5chV) Operating Conditions Temperatures 0 - 45°C Humidity 15 to 90% RH, (non-condensing) Power Supply Rechargeable batteries, USB Charging Physical Characteristics Weight Approx. 0.625g Dimensions 216mm x 105mm x 45mm KANE 258 MANUAL...
  • Page 24: Eu Declaration Of Conformity

    This declaration of conformity is issued under the sole responsibility of the manufacturer:- Kane International Ltd. Kane House, 11 Bessemer Road, Welwyn Garden City, Hertfordshire. AL7 1GF, UK. Tel: +44 1707 375550 Web: www.kane.co.uk The KANE458s is in conformity with the relevant Union harmonization legislation below:...
  • Page 25: Service - Calibrate - Recertify

    SERVICE – CALIBRATE – RECERTIFY All analysers & pressure meters should be recertified annually. Extend your KANE analyser & pressure meter’s ‘no quibble’ warranty up to 10 years by returning your analyser & pressure meter via your KAM dashboard annually.
  • Page 26: Kane Asset Manager (Kam)

    Report Stolen: Reporting your analyser stolen ensures our Stolen Analyser Register is up-dated & helps prevent industry colleagues unknowingly buying stolen goods • Remove your KANE Analyser once sold so its new owner can also benefit There are different KAM options & we'd be delighted to discuss your individual requirements More than 4 FGAs? Contact: support@kane.co.uk...
  • Page 27 Your support - our way KANE 258 MANUAL...
  • Page 28: Guaranteed Same Day Despatch

    Book & pay to Service & Recertify via your KAM dashboard Select FREEPOST for tracked carriage - UK mainland only Your analyser will be despatched on the same day we receive it... OR YOUR MONEY BACK 28 KANE 258 MANUAL...
  • Page 29: Where To Send Your Analyser

    Northern Customer Service Southern & International Customer Kane International Ltd Service Gibfield Park Avenue Kane International Ltd Atherton, Kane House, 11 Bessemer Road Manchester Welwyn Garden City M46 0SY, UK Hertfordshire e: nservice@kane.co.uk AL7 1GF, UK t: 0800 059 0800 e: sservice@kane.co.uk...
  • Page 30 THIS PRODUCT CONFORMS WITH THE FOLLOWING PLEASE RECYCLE MADE IN THE UK 30 KANE 258 MANUAL...
  • Page 31 Before use, please register on our website www.kane.co.uk Scan the QR code to go directly to register your product online. Kane International Ltd Kane House, 11 Bessemer Road Welwyn Garden City Hertfordshire AL7 1GF, UK email: sales@kane.co.uk telephone: 0800 059 0800...