Code
Text
E1410
CPU # IERR
E1414
CPU # Thermtrip
E1418
CPU # Presence
E141C
CPU Mismatch
E141F
CPU Protocol
E1420
CPU Bus PERR
E1422
CPU Machine Chk
E1610
PS # Missing
E1614
PS # Status
E1618
PS # Predictive
Maintaining and Troubleshooting the Dell
18
PowerEdge
R610 Server
Causes
failure will put the system at
risk of over-heating.
Specified microprocessor is
reporting an internal error.
Specified microprocessor is
out of acceptable
temperature range and has
halted operation.
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
Processors are in an
unsupported configuration.
The system BIOS has
reported a processor protocol
error.
The system BIOS has
reported a processor bus
parity error.
The system BIOS has
reported a machine check
error.
No power is available from
the specified power supply;
specified power supply is
improperly installed or faulty.
No power is available from
the specified power supply;
specified power supply is
improperly installed or faulty.
Power supply voltage is out
of acceptable range;
specified power supply is
improperly installed or faulty.
PowerEdge
Comments on this document? infodev@avaya.com
Corrective action
limits, then escalate for possible
server replacement.
Check control panel LCD for
additional scrolling messages.
Escalate for possible server
replacement.
Check room temperature and external
air flow. If both are within acceptable
limits, then escalate for possible
server replacement.
Note:
The LCD continues to display
this message until the system's
power cord is disconnected and
reconnected to the AC power
source.
Escalate for possible server
replacement.
Run server diagnostics. This requires
a keyboard and monitor.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible power supply
replacement.
Escalate for possible power supply
replacement.
Escalate for possible power supply
replacement.