4. Sampler Location

4.1 The sampler should be a minimum of five pipe diam-
eters from any device which could cause aerosols or
significant pressure drops.
4.2 The sampler should not be located within the defined
meter tube region (AGA 3-1985 ED.).
5 Ø
A = The number of unobstructed, straight pipe diameters
upstream (see AGA - 3 manual).
B = The number of unobstructed, straight pipe diameters
downstream (see AGA - 3 manual).