11. Troubleshooting
Non-linear/linear flow input
The Z-200 controller is capable of receiving two types of flow
outputs: non-linear and linear.
A. Non-Linear: when using differential pressure transmitter
inputs that are not linear with respect to flow, the configura-
tion jumper should be in the factory setting to the far left
position marked non-linear.
B. Linear: when using flow computer type flow inputs that
are linear with respect to flow, the configuration jumper
should be in the middle position marked linear.
Factory
Mutual
System
Approved
Factory setting for non-linear
flow input using the DPT
Factory
Mutual
System
Approved
Setting for linear flow input