11. Troubleshooting

timer mode #5
Proportional-to-time
A. Set the mode switch to position #5.
B. Set the data switches to 00.0 to enter the diagnostic
mode of operation.
C. Depress the enter switch to load the value into the
memory.
D. This mode of operation enables the operator to increase
the solenoid output rate to one actuation every two seconds.
NOTE: the LCD stroke indicator should increment each
time the solenoid actuates.
LED Indicator Chart (proportional-to-time only)
green
red
on
off
off
on
NOTE: on means for approximately one half second.
To test the LED indicators, depress the test switch located
on the front of the controller.
Timer Setting
A. Z-200/6.1 - all time settings are xx.x minutes
B. Z-200/6.10 - all time settings are x.xx minutes.