Provisioning
Table 5. H4TU-C-319 List 1 Standard Config Menu Options (Continued)
Standard Config
Screen
Menu Options
Display Code
H4TU-R TLOS
TLOS
Loopback
Network Loopback
NLBP
Pattern
Power Back Off -
PBON
Network
See
"Power Back Off
(PBON and PBOC)
Options" on page
22.
Power Back Off -
PBOC
Customer
See
"Power Back Off
(PBON and PBOC)
Options" on page
22.
ADC Config Menu
Screen
Options
Display Code
Line Power Feed
PWRF
Remote Provisioning RTPV
Bipolar Violation
BPVT
Transparency
See
"Bipolar
Violation
Transparency
(BPVT) Option" on
page
22.
DS1 BER Threshold
DBER
See
"DS1 Bit Error
Rate (DBER) Option"
on page
22.
20
Selection
Description
ENA
Enables a logic loopback at the H4TU-R when an LOS occurs at its DS1 input.
For priority resolution, see
DIS
Disables TLOS logic loopback.
AIS
Enables the H4TU-R to transmit AIS towards the CI for any network loopback.
For priority resolution, see
LOS
Enables the H4TU-R to transmit LOS towards the CI for any network
loopback.
DEF
Configures the power output levels of the H4TU-C network unit toward the
customer to comply with the Default template as defined in Section 6.1.4.2 of
ANSI T1.418.
ENH
Configures the power output levels of the H4TU-C network unit toward the
customer to comply with the Enhanced template as defined in Section 6.1.4.2
of ANSI T1.418.
DEF
Configures the power output levels of the H4TU-R customer unit toward the
network to comply with the Default template as defined in Section 6.1.4.2 of
ANSI T1.418.
ENH
Configures the power output levels of the H4TU-R customer unit toward the
network to comply with the Enhanced template as defined in Section 6.1.4.2
of ANSI T1.418.
Table 6. H4TU-C-319 List 1 ADC Config Menu Options
Selection
Description
OFF
Disables powering to the HDSL4 pair.
LOW
Keeps the HDSL4 line voltage at nominal -185 Vdc.
HIGH
Keeps the HDSL4 line voltage at nominal ±123 Vdc.
AUTO
Keeps the H4TU-C line voltage at -185 Vdc when line powering up to two
devices (one doubler and one remote unit, or two doubler units). When line
powering of more than two devices is required, the line unit automatically
switches to ±123 Vdc.
ENA
Enables remote provisioning.
DIS
Disables remote provisioning.
ENA
Enables BPVs and HDSL4 CRC errors at the DS1 input to be converted into
DS1 BPVs at the DS1 output at the distant end. This makes HDSL4
transparent to BPVs.
DIS
Disables BPV Transparency.
ENA
Enables the fixed 24-hour DS1 BER threshold.
DIS
Prevents the generation of a system alarm due to DS1 BER.
September 12, 2003