ASCM 14; ASCM 14QX; ASCM 18; ASCM 18QX; ASCM 18QM
8. Troubleshooting
Fault
Motor not running
Unusual noise (rattling)
Motor only turning in one direction
Torque shutting off at drilling level or too
early
C-SC_CSSM
Version 1.0
Cause
Motor / electronics defective
Switch is defective
Battery plug contacts have come loose
Gearbox is defective
Plug on motor has come loose or is not secure
Adjusting ring is defective
08.06.2017
All rights reserved by FEIN, especially in case of industrial rights registration.
FEIN retains all rights of disposal, such as copying and circulation
Remedy
Check electrics with test board
Check electrics with test board
Check components
Replace gearbox
Check cable
Replace adjusting ring
.
Page 36 of 40