High Pot. And Insulating Resistance Tests; Cloning; Shop-End Test; How To Upgrade Sw Flash Using Mtk Tool - TCL U65S9906 Service Manual

Hide thumbs Also See for U65S9906:
Table of Contents

Advertisement

Important: If measurements are performed on whatever else LED panel with Minolta CA210, it's required to
calibrate additional channel (ex: CH01) using relative following offsets (CH00 remains for CCFL panel):
for "
".
+0.012
y
and
See WB list as follows for more details.
Note⑧:

Cloning

Once a TV is well aligned and prepared (channels maps, volume, picture presets, ...) , user can prepare golden
clone image that can be copied on demand to all further TV production lot of same TV. To access cloning function, you
can select "Factory menu USB Clone && UpdateAll Clone/CH Clone/User data Clone" , Scroll down to "TV to
USB" or "USB to TV" and press RCU "OK/►" key to process. 4 BIN images can created, overwritten or read on USB
stick (pen drive) depending on chosen template like following: "database\applications\database\***.db" . These files
need to be used strictly with MT58 SoC platform as depending on SW structure.
Other faster access methods via UART/IR commands are available on enclosed SIACP requirements (rev. v3.9).

2.4. High Pot. and Insulating Resistance Tests

At the end of the process, a "High Voltage" and an "Insulating Resistance" tests are required to fulfil Safety
Electrical requirements (CEI 65065).
 High Voltage Withstanding requirements
- "Voltage"
- "Max Leakage Current"
- "Test Time"

2.5. SHOP-END Test

At final process stage, it's necessary to perform "Reset shop" before any packing to leave Factory mode and
restore User default presets.
This function is accessible by selecting "Factory menu Reset Shop", then pressing RCU "OK/►" key. Other
faster methods via UART/IR commands are available on enclosed SIACP requirements (rev. v5.4).
A password might be required in case of Parental Control function is locked, use default "1234" password or
Note⑨:
"0423" super password to clean-up existing ones if forgotten.
Appendix ⑴ "How to upgrade SW FLASH using MTK tool"
 Download boot bin " tcl_m1v1_eu_secure_emmcboot.bin" & blank upgrade main software"V8-T658T01.pkg"
from the software website.
Connect UART interface to suitable manufacturing TV input connector, upgrade boot bin first to blank IC.
1) Turn on your TV, then connect the Serial Interface to USB debug port.
Test and Alignment Specification for MT58 Series (v0 01)
3500 VAC
10 mA
3 sec
END
Page 14 of 26
 Insulating Resistance requirements
- "Voltage"
- "Threshold Min"
- "Test Time"
160523
for "
+0.002
500 VDC
4M Ω
2 sec
"
x