4-1-4 Cable clamp fitting

Use the following types of grounding plate and cable clamp fitting to strengthen the noise resistance
of the communication cable. The grounding plate can be installed onto the terminal block cover of the
I/F unit (HS-IF-6). Peel part of the cable sheath as shown in the drawing to expose the shield sheath,
and press that section against the grounding plate with the cable clamp fitting.
Grounding plate (E) outline
* Always wire the grounding wire from the grounding plate to the
cabinet grounding plate.
Chapter 4 Option and Peripheral Devices
70
24
6
3
56
Cable clamp
fitting A, B
Grounding bar
Shield sheath
Cable clamp fitting outline
2-φ5 hole
Installation hole
11
M4 screw *
4–13
Grounding plate
MAX L
10
L
Fitting A
70
Fitting B
45