Rebar or stake (by others)
Finished grade
8. Remove temporary cover and pull out low
voltage wire.
10. Mount faceplate to collar using (2) #6-32x5/8"
flat head screws (provided) with a 5/64" Allen
Stability flange
Rebar or stake (by others)
wrench.
Pea gravel or sand
Finished grade
2 window
faceplate
shown
Faceplate
THIS PRODUCT IS AVAILABLE WITH A FACTORY INSTALLED LED.
COMPONENT REPLACEMENT - IF REQUIRED
Optical opening on
faceplate will align with
BKSSL
alignment arrows on
temporary cover
Power Pipe™
Stability flange
2 window
Pea gravel or sand
faceplate
shown
1. Loosen #8-32 set screw on faceplate assembly
using a 5/64" Allen wrench and remove.
Optical opening on
faceplate will align with
Loosen set screw on collar and remove.
alignment arrows on
temporary cover
Stability Flange
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
Wire nuts must
clear opening
Surface Mount Installation
Stability flange
Concrete
Pea gravel or sand
2 window
faceplate
shown
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
WIRING DIAGRAM
LINE
COM
Stability flange
Concrete
Pea gravel or sand
Collar
Optical opening on
MINI-MICRO ™ DRIVESTAR™
faceplate will align with
alignment arrows on
temporary cover
PROJECT:
6"
min.
Finished grade
LINE
12V
Remote
Transformer
COM
COM
Finished grade
8 3/4"
12V
Remote
Transformer
FIXTURE
COM
Finished grade
8 3/4"
2 window
faceplate
shown
Finished grade
2 window
faceplate
shown
Optical opening on
faceplate will align with
8 3/4"
alignment arrows on
Optical opening on
faceplate will align with
temporary cover
alignment arrows on
temporary cover
Power Pipe™
LINE
12V
Remote
Transformer
FIXTURE
COM
COM
2. Pull the heat sink from the body to expose
the LED board and Driver components. Utilize
quick disconnects to change modular LED
and driver components. Re-install the heat
Finished grade
sink into body.
8 3/4"
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
TYPE:
6"
min.
Finished grade
FIXTURE
9. Access low voltage wire inside Power Pipe™. Make
two watertight connections using waterproof
wire connectors (By Others). Wire nuts must clear
opening. Insert fixture and low voltage wire into
Rebar or stake (by others)
Power Pipe™.
Finished grade
Rebar or stake (by others)
Rebar or stake (by others)
Stability flange
Concrete
Finished grade
Pea gravel or sand
Finished grade
Temporary cover
Surface mount collar
Power Pipe™
3. Replace faceplate assembly and tighten set
screw. Re-Install fixture.
Rebar or stake (by others)
Stability flange
Concrete
Finished grade
Pea gravel or sand
RELEASED
11-21-16
Wire nuts must
Concrete
clear opening
Stability flange
Concrete
Pea gravel or sand
Stability flange
Concrete
Pea gravel or sand
2 window
faceplate
shown
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Stability Flange
REFERENCE NUMBER
INS001068.1
2 w
fa
sh
Surface
face
Pow
a
Need help?
Do you have a question about the MINI-MICRO DRIVESTAR and is the answer not in the manual?