Installation Instructions
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted lamp is HOT!
WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing lamp.
Lamp gets HOT quickly! Contact only switch/plug when turning on.
Do not touch hot lens, guard, or enclosure
(see diagram/picture).
Keep lamp away from materials that may burn.
Do no touch the lamp at any time. Use a soft cloth.
Oil from skin may damage lamp.
Do not operate the luminaire fitting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
This set of instructions works for:
LINE
LT - Litestick™
Transformer
(by others)
LT-L - Litestick™ Style L
LT-T - Litestick™ Style T
COM
Optional
Finished grade
Stability Flange
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
Finished grade
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
& Low Voltage Halogen
Warning
Flammable
Hot Surface
•
Optional
Finished grade
Stability Flange
•
•
•
•
IMPORTANT LISTINGS AND CERTIFICATIONS
· SUITABLE FOR WET LOCATIONS
Remote
12V
FIXTURE
COM
LT-L
Optional Stability
Flange
LT-T
Optional
Stability Flange
High Voltage
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local
and Provincial Codes.
Follow product label information and instructions.
Qualified Personnel must perform all servicing or relamping of
this product.
Before wiring to power supply and during servicing or relamping,
turn off power at fuse or circuit breaker before service.
The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause
an unsafe condition and void product warranty.
· SUITABLE FOR IN-GROUND RECESSED INSTALLATION
™
Power Pipe
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
LT™/ LT-L™/ LT-T™
TOOLS
TOOLS
5/64" Allen Wrench
NEEDED:
NEEDED:
Phillips Screwdriver
Waterproof Wire Connectors
By Others
By Others
•
Do not block light emanating from product in whole or part,
as this may cause an unsafe condition.
•
Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
•
Entire fixture may become extremely hot. Do not touch hot
lens or fixture body. Do not touch the lamp at any time. Use
a clean, dry, soft cloth to handle the lamp. Oil from skin may
damage the lamp and cause it to rupture.
•
Replace lamp only with correct wattage and type of lamp
marked on fixture label.
•
All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
LT
Fixed
Adjustable
Stem
Stem
18 Gauge Wire
Finished grade
Pea gravel or sand
Fixed Stem
with
T - housing
option
DATE
REFERENCE NUMBER
11-30-16
INS001109