Download Print this page

B-K lighting INTEGRAL DENALI Series Installation Manual

Advertisement

Quick Links

Surface Mount Installation
Warning
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY
TO PERSONS IMPORTANT
SAFETY INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time.
Use a soft cloth or gloves. Oil from skin may cause
damage.
SAVE THESE INSTRUCTIONS
Proper soil preparation is required before installation. See the DIG-IT guide at www.bklighting.com/collaterals/install/digit.pdf
Faceplate
18/3 Ga. Wire
PVC Housing
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR
SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
INTEGRAL DENALI SERIES UPLIGHT
Flammable
Hot Surface
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local
and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause
an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Surface
Mount Collar
Body
NEEDED
FOR
INSTALLATION:
By Others
High Voltage
SAFETY AND INSTALLATION INSTRUCTIONS
for more information.
INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
5/64", 9/64" & .050" Allen Wrench
Waterproof Wire Connectors
Silicone
• Do not block light emanating from product in whole or part,
as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type
of power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause
an unsafe condition and void product warranty.
INSTALLATION
Surface mount uplights are intended for installation in
wood, pavers, stone, and other hardscapes.
Not recommended for concrete pour
installations.
RELEASE DATE
REFERENCE NUMBER
08/02/2021
INS-2826-00

Advertisement

loading

Summary of Contents for B-K lighting INTEGRAL DENALI Series

  • Page 1 • info@bklighting.com THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
  • Page 2: Surface Mount Installation

    INTEGRAL DENALI SERIES UPLIGHT Surface Mount Installation PROJECT: TYPE: 5-1/2” O.D. 5” O.D. Drill 5” diameter hole into mounting surface 2. Loop minimum of 6” of wiring inside housing 3. Place housing into hole. Surface mount collar at uplight installation location as per lighting to allow for fixture service.
  • Page 3: Fixture Installation

    INTEGRAL DENALI SERIES UPLIGHT Finished grade Surface Mount Installation 8 3/4” In-Ground Installation Instructions Soil Prep Excavated for Housing Conduit trench Rebar or stake (by others) Stability ange 2 window Finished grade Pea gravel or sand faceplate shown Conduit Trench A.
  • Page 4: Wiring Diagram

    INTEGRAL DENALI SERIES UPLIGHT Surface Mount Installation In-Ground Installation Instructions LINE LINE Wire nuts must FIXTURE 6” GROUND GROUND clear opening min. Finished grade 8. Remove temporary cover and pull out primary 9. Access primary 120v, branch circuit WIRING DIAGRAM 120v, branch circuit wiring.
  • Page 5 INTEGRAL DENALI SERIES UPLIGHT Surface Mount Installation PROJECT: TYPE: This product is available with field replaceable components. Exclusive interchangeable OPTIKITS and modular LED components with quick disconnects simplifies upgrades and maintenance when necessary. Fixture Relamping Remove faceplate from collar using (2) #8-32 2.
  • Page 6 INTEGRAL DENALI SERIES UPLIGHT Surface Mount Installation This product is available with field replaceable components. Exclusive interchangeable OPTIKITS and modular LED components with quick disconnects simplifies upgrades and maintenance when necessary. 12. Twist to reinstall optic onto optic holder. 13. Tighten three (3) #8-32 set screws with a 14.

This manual is also suitable for: