Alarm Management - Palazzetti Ecofire Dani Use And Function

Table of Contents

Advertisement

Available languages

Available languages

5 ALARM MANAGEMENT

The stove is supplied with an automatic status control
system. When a system anomaly is detected, an error
List of alarms and possible causes:
CODE
ERROR/WARNING
E 0 0 4
Communication error
NO CONNECTION
E 1 0 1
Start-up failure
NO IGNITION
E 1 0 2
Temperature of fumes is too low
EXHAS.TEMP.
E 1 0 3
EXHAUST FAN
E 1 0 4
Black-out
BLACK OUT
E 1 0 5
Pellet probe alarm
PELLET PROBE
E 1 0 8
Safety error
THERMAL
E 1 0 9
Pressure error
DEPRESS
E 1 1 0
Temperature probe malfunction
ROOM PROBE
E 1 1 1
Exhaust probe malfunction
SMOKE PROBE
E 1 1 2
P ELL ET TE MP
Alarm reset:
ON button for a little while.
In the event of error code
thermostat located at the back of the unit before resetting
At this point you can restart the stove.
DESCRIPTION
E 1 0 8
, reactivate the manual
POSSIBLE CAUSES
has been interrupted or disconnected
Hopper is empty
Pellet quality
Dirty brazier
Check the pellet level in the hopper and that brazier is
clean and in the correct position.
Check that the door and the ash box are properly closed.
Pellet probe is disconnected or faulty
Inadequate combustion air intake
Faulty air probe
Faulty exhaust temperature probe
Possible ventilator fault