Booster pump
Table of Contents

Advertisement

2. Install quick connect
fittings and flexible hose.
(R0617100), (R0621000),
(P19)
• Apply four (4) to six (6)
wraps of PTFE (Teflon
tape to the tapered thread
of the connector barb.
Be sure to wrap the tape
around the threads in
the OPPOSITE direction
that the connector
will be rotating during
installation. This will
ensure a proper water
tight seal.
• Thread and tighten the
tapered thread of the
connector barb into the pump
port on the pump body.
• Trim reinforced hose to
required length. Make sure
cut is clean and square. Avoid
unnecessary loops or bends in the hose.
• Slide connector nut onto the trimmed end
of the hose with threaded end toward the cut end of the hose.
• Apply water to connector barb to help hose slide over barbs. Push trimmed edge
of hose fully onto the connector barb.
• Slide/Rotate the connector nut to the barb to engage threads correctly, do
not cross thread connector nut. Tighten the connector nut until threads are no
longer visible (gap about 1/8" or just less than the width of two dimes), or until
it touches the barb face.
Zodiac Pool Systems, Inc.
2620 Commerce Way, Vista, CA 92081
1.800.822.7933 | www.polarispool.com
Zodiac Pool Systems Canada, Inc.
2115 South Service Road West, Unit 3
Oakville, ON L6L 5W2
1.888.647.4004 | www.ZodiacPoolSystems.ca
ZODIAC
®
is a registered trademark of Zodiac International,
S.A.S.U., used under license. All other trademarks referenced
herein are the property of their respective owners.
©2016 Zodiac Pool Systems, Inc. H0609200_REVA
PTFE (Teflon
)
®
) Tape
c
b
a
Quick Connect Nut
Reinforced Hose
Pump Inlet
Barbed Fitting