1500 w | forced air quartz infrared element (20 pages)
Summary of Contents for Heat Storm DIAMANT
Page 1
INSTRUCTION FOR INSTALLATION AND USE - GARANTY You have just acquired this radiant radiator DIAMANT/EMERAUDE And we thank you for your choice. This device has been studied, designed and realized with care, In order to give you full satisfaction. NO-135003A - ILO DIAMANT/EMERAUDE INSTRUCTION MANUAL ECODESIGN US...
I. Markings and indications DIAMANT/DIAMANT/EMERAUDE 400 x 1200 cm / 16’ x 48’ reference : THERMAL POWER Nominal Thermal Power P nom Minimal Thermal Power ( indicative) P min Maximal Thermal Power (constant) P max AUXILIARY ELECTRICAL CONSUMPTION At nominal thermal power...
(cable type SJOOW 14/2). The system complies with current standards (see technical data). The radiator DIAMANT/EMERAUDE is only suitable for indoor use. It is suitable for all the rooms of the housing, including bathrooms thanks to a suitable protection (Double insulation - Class II).
Page 5
Thoroughly test the radiator before installation and ensure that no hot spots develop. Only use the radiator DIAMANT/EMERAUDE for the recommended applications and with the DIAMANT/EMERAUDE accessories offered (bars, regulation) for an effective guarantee. Do not attempt to disassemble the unit (loss of warranty).
Do not cover the heating facade to ensure radiation efficiency and avoid accidental overheating. Cut off the radiator DIAMANT/EMERAUDE with the switch and wait for it to cool down to clean it with a soft, damp cloth. Do not let a child unattended take care of A long contact with the glass can burnt The radiant surface can reach 80°C (176°F).
(See package insert). Towel bars can be added To your radiator DIAMANT/EMERAUDE before fixing it to the wall To turn it into a real towel dryer: ideal for your bathroom (accessories supplied separately). TOOLS REQUIRED FOR INSTALLATION...
INSTALLATION AND FITTING To facilitate installation of your DIAMANT/EMERAUDE radiator, a template is provided. It is represented on the back of the packaging (actual dimensions). • Reminder of drilling centers HORIzONTAL SPACING In mm HORIZONTAL VERTICAL SPACING SPACING DIAMANT/EMERAUDE 966 / 38,03’...
• Attaching the radiator to the wall Fix the 2 wall brackets with 4 dowels and 4 screws adapted to the material of your wall. Glue the 4 foam pads underneath each Hole as shown in the illustration opposite. Position the radiator on the wall brackets By sliding it correctly into the holes.
• Electrical connection Connect electrically. L = Phase (brown) N = Neutral (blue) The electrical connexion must be made with a IPX4 box , class II, in compliance with regulation. PILOT WIRE = FP (black) Do not plug in if you are not connected to an automated system that manages the Pilot wire.
V. Help with diagnosis NATURE OF THE PROBLEM CONTROL ACTION 1. Ensure that the green light is Turn the function button lighting (power) and the red light (The switch on the side is lighting too of device) to position I or II 2.
VI. Guarantee • 5 years for the heating element of the radiator DIAMANT/EMERAUDE and 2 years for the Programmable electronic thermostat. • The warranty period starts from the date of purchase on the Invoice or receipt. • This warranty applies in addition to all standard laws. GUARANTEE CONDITIONS Any request for guarantee is subject to compliance with the following terms and conditions: • This warranty is valid only for domestic use in dry space. • The warranty covers defects arising during the manufacture of the equipment. It does not extend to damage caused by third parties (eg transport or assembly).
Page 14
GUARANTEE CERTIFICATE In case of damage during the warranty period or later, please Contact the manufacturer below: • email : derrick@heatstorm.com • HOT LINE : +1 435.752.6611 In the case of a return service, please attach this document filled with the invoice. N ame: Email : Street : Product : ZIP code: Date of purchase :...
Need help?
Do you have a question about the DIAMANT and is the answer not in the manual?
Questions and answers