5 Insert the plug K into the wall-socket (230 Volts - AC / 50 Hz) and set the
correct time using the adjustment keys O (refer to Section C).
6
Your Zibro is now ready for use.
B
FILLING FUEL
Fill the removable tank in a suitable place since there can always be some spillage.
C
Follow the procedure below:
1
Make sure that the heater is switched off.
2
Open the upper lid and lift the removable tank out of the heater (Fig. B).
Note: Some drops may leak from the tank. Put down the removable tank (cap
pointing upwards, handle on floor (Fig. C) and screw off the fuel cap.
D
3
Fill the removable tank using a fuel pump (refer to fuel pump operation
instructions.) Make sure that it is in a higher position than the removable tank
(Fig. D). Insert the ribbed hose into the opening of the removable tank.
4
Check the removable tank fuel gauge while filling the tank (Fig. E). Stop
filling once the gauge indicates that the tank is full. Never overfill the tank,
especially not when the fuel is very cold (fuel expands when it heats up).
5
Check whether the fuel cap is straight and tightened properly. Reinstall the
removable tank in the heater (cap down). Close the lid.
E
C
SETTING THE CLOCK
It is only possible to set the correct time and day, when the heater is connected to
the mains and not burning. Use the adjustment keys O to set the time and day/set
(weektimer) S to set the day.
empty
full
First press one of the three keys to switch on the function (the 4-digit L will start
blinking). Next, set the hours using the key (N hour) and the minutes using the
key (M min.) and the day using the key extension day/set S.
Press once to increase the value by one step. When you hold down the key, the
value will continue going up, until you release the key again. After approximately
F: When the 4-digit stops
10 seconds the 4-digit will stop blinking and the setting will be locked. 5 minutes
blinking, the setting
after switching off the heater, the information on the display will disappear and
has been locked to the
the heater will automatically switch into the stand-by position.
indicated value.
When the heater has been unplugged for more than 30 minutes (or after a
power failure), the time and the day need to be set again.
4
78
p074_087_uk_SRE346E.indd 78-79
D
IGNITING THE HEATER
When used for the first time, a new heater may give out a smell for a short while.
You should therefore provide extra ventilation.
Always ignite the heater with the
lighter. Just press the
The button will start blinking, indicating that the ignition procedure has started.
This will take a short while. Once the heater is burning, the
lit (red). The information display L will show two numbers (Fig. G). The actual
room temperature is indicated below ROOM, while the temperature setting is
indicated below SET. The latter can be changed with the adjustment keys (refer to
G: The required
Section E).
temperature on the
left, the measured
Prior to igniting the heater, always check for sufficient fuel in the removable tank.
temperature on the right.
E
SETTING THE REQUIRED TEMPERATURE
The temperature setting can only be adjusted, when the heater is burning. Use
the adjustment keys O to adjust the temperature. First press either of the two
keys to switch on the function (the °C mark and 4-digit L will start blinking). Next,
adjust the temperature using the key (Mmin.) to set the temperature to a higher
setting and the key (Nhour) to lower the temperature. Press once to increase the
value one step. After approximately 10 seconds the °C mark and 4-digit will stop
blinking and the setting will be locked (Fig. F).
The available temperature settings range from 6°C minimum to 28°C maximum.
When the heater has been unplugged for more than 10 minutes (or after a power
failure), the temperature will reset to the factory setting of 20°C.
F
SWITCHING OFF THE HEATER
There are two ways to switch off the heater.
1
Press the
signal. Within approximately one minute the flame will have extinguished.
2
Press the TIMER key P, when you want to switch off the heater and ignite it
again with the timer the next time. This not only switches off the heater, but
it also activates the timer function.
G
THE INFORMATION DISPLAY
The information display L not only serves as an indicator of the (set) time and
temperature (Sections C, E, and F), it also indicates any malfunctioning of the
heater. The code on the information display tells you what is the matter:
CODE
INFORMATION
e - 0
Temperature within the heater too high.
In case of any
f - 0
Power interrupted.
malfunctioning the
e - 1
Faulty thermostat.
information display
f - 1
Faulty burner thermistor.
will tell you what is the
matter.
button M. Never use matches or a cigarette
button M to ignite the heater.
button M will remain
button M. The information display will show the CLOCK
WHAT TO DO
Cool-down and re-ignite.
Re-ignite the heater.
Contact your dealer.
Contact your dealer.
4