11. Product overview
3. Warnings

11.2. Additional front panel operations and indications

11.2.1. Frame reset

A factory reset and soft reset can be performed from the front panel. A factory reset will restore all settings to
original defaults, including network settings, frame presets and current settings. A soft reset reverts only the current
settings to default. Network settings and frame presets are not changed with a soft reset.
1. Place the frame in standby mode.
2. Press and hold Select and channel 3 mute button. Then press the power button.
3. User interface will illuminate available options. Choose from the options below
a. Press channel 1 mute button (red LED) to initiate the factory reset sequence.
b. Press channel 2 mute button (amber LED) to initiate the soft reset sequence.
c. To cancel, press channel 4 mute button (green LED).
4. Wait state indication is present while either reset is performed.
5. To complete the factory reset process, cycle the mains power by completely removing the power plug and
reinserting it.
11.2.2 Wait indication
Wait indication is displayed when the frame is performing an operation. All LEDs except power are unlit and a
circling amber light is displayed on channels 1 and 2.
11.2.3 Power cycle required indication
After an operation that requires a subsequent power cycle to complete, the power LED blinks alternately red and
green. A power cycle requires that the mains are completely removed from the device and not connected again
until the device has powered off.
11.2.4. Front panel lock
The front panel can be disabled from the Lake Controller. When the front panel is disabled, LEDs 4, 8 and 9 (all
buttons on the lowest row) ash in amber when hitting any touch button.