7.3: Resetting to factory defaults
Reset procedure allows to restore the device back to its factory set-
tings, which means all information about the Z-Wave controller and
user configuration will be deleted.
1. Press and hold the button to enter the menu.
2. Release button when the device glows yellow.
3. Quickly click the button to confirm.
4. After few seconds the device will be restarted, which is signalled
7.4: Testing operation
The built-in button allows to test device operation as follows:
7: operatInG tHe DeVIce
Resetting the device is not the recommended way of
i
removing the device from the Z-Wave network. Use re-
set procedure only if the primary controller is missing or
inoperable. Certain device removal can be achieved by the
procedure of removing described.
with the red colour.
1xclick button – switch OUT1 output
2xclick button – switch OUT2 output