4.8: Connection with button
You can connect monostable or bistable switches to IN1/IN2 termi-
nals to activate scenes.
1. Disconnect power.
2. Connect with the diagram below:
Diagram 8: Example connection with 2 buttons
3. Verify correctness of connection.
4. Power the device.
5. Add the device to the Z-Wave network.
6. Change values of parameters:
Connected to IN1:
» Monostable: change parameter 20 to 2
» Bistable: change parameter 20 to 3
Connected to IN2:
» Monostable: change parameter 21 to 2
» Bistable: change parameter 21 to 3
2
1
IN2
IN1
GND
P
GND 9-30V
(1,2 – button)