Problem Solving - Philips SBCSC486/85 Instructions For Use Manual

Philips dect baby monitor sbcsc486
Hide thumbs Also See for SBCSC486/85:
Table of Contents

Advertisement

SC486_book.qxd 23-09-2004 18:22 Pagina 15
Problem
DECT SYSTEM
LINK light does
not light
High pitched noise
Parent Unit
batteries do not
charge
No sound/ Cry of
baby is not heard
Parent unit reacts
on other ambient
sounds
Battery check light
lights (Baby Unit) or
blinks (Parent Unit)
DECT SYSTEM
LINK light (flashing
red)/ System check
alarm beeps on
Parent Unit

Problem solving

If a fault occurs, first check the points listed below. If you are unable to
remedy a problem by following these hints, contact the helpline or consult
your dealer.
Under no circumstances should you try to repair the set yourself as this will
invalidate the guarantee.
Possible cause
Parent Unit: unit is not turned on.
Baby Unit: unit is not turned on.
Batteries are low.
Power adapter is not plugged in or
batteries are exhausted.
Rechargeable batteries not inserted
into Parent Unit.
Units are too close to each other.
Volume too high.
Battery life is at an end.
Battery polarity misfitted.
Poor contact between Unit and
Charger.
Volume on Parent Unit is set too low.
Sensitivity setting on Parent Unit too low. Adjust sensitivity level of Parent Unit.
Units are out of range.
Ambient sounds other than the baby,
trigger the transmission.
Batteries are low or empty.
Parent Unit:
Baby Unit:
Units too far away from each other.
Batteries are low.
Units cannot establish a connection,
even when close to each other.
No power to one of both units.
ENGLISH
Solution
A
Press the
button (26).
A
Press the
button (7)
Replace/recharge batteries.
Plug in power adapter or replace batteries.
Place rechargeable batteries.
Move Parent Unit away from Baby Unit.
Decrease the Parent Unit volume.
Replace rechargeable batteries,
using only NiMH rechargeable batteries.
Fit battery in correct polarity position.
Clean Charger contact with soft dry cloth.
Increase Parent Unit volume.
Move Parent Unit closer to Baby Unit.
Move the Baby Unit closer to the baby
and try lowering the sensitivity on the
Parent Unit.
Recharge or replace batteries.
Replace or remove battery.
Decrease distance between units.
Replace/recharge batteries.
Try solving the problem by using the factory
initialisation mode. For this see chapter
'Factory Initialisation mode'.
A
Check
button (26) on Parent Unit
A
and
button (7) on Baby Unit.
15