SafEye
800 Series
Diagnostic Kit

Instruction Manual

THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL
HAVE THE RESPONSIBILITY FOR USING OR SERVICING THE PRODUCT. Like any piece of
complex equipment, this instrument will perform as designed only if it is used and serviced
in accordance with the manufacturer's instructions. OTHERWISE, IT COULD FAIL TO
PERFORM AS DESIGNED AND PERSONS WHO RELY ON THIS PRODUCT FOR THEIR
SAFETY COULD SUSTAIN SEVERE PERSONAL INJURY OR LOSS OF LIFE.
The warranties made by Mine Safety Appliances Company with respect to the product are
voided if the product is not used and serviced in accordance with the instructions in this
manual. Please protect yourself and others by following them. We encourage our cus-
tomers to write or call regarding this equipment prior to use or for any additional infor-
mation relative to use or repairs.
In North America, to contact your nearest stocking location, dial toll-free 1-800-MSA-INST
To contact MSA International, dial 1-412-967-3354.
© MINE SAFETY APPLIANCES COMPANY 2007 - All Rights Reserved
This manual is available on the internet at www.msanet.com
Manufactured by
MSA NORTH AMERICA
P.O. Box 427, Pittsburgh, Pennsylvania 15230
(L) Rev 0
TM
Xenon
"! WARNING
IMZ001-034
10085905

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SafEye Xenon 800 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for MSA SafEye Xenon 800 Series

  • Page 1: Instruction Manual

    In North America, to contact your nearest stocking location, dial toll-free 1-800-MSA-INST To contact MSA International, dial 1-412-967-3354.
  • Page 2 MSA Permanent Instrument Warranty 1. Warranty- Seller warrants that this product will be free from mechanical defect or faulty workmanship for a period of one year for the General-Purpose Diagnostic Kit and two years for the Intrinsically-Safe Diagnostic KIt from date of shipment, provided it is maintained and used in accordance with Seller's instructions and/ or recommendations.
  • Page 3 General Warnings " WARNING 1. The instruments described in this manual must be operated and maintained in strict accordance with its labels, cautions, warnings, instructions, and within the limitations stated. 2. Alteration of the Diagnostic Kit, beyond the scope of this manual or by anyone other than authorized service personnel, could cause the product to fail to perform as designed, and persons relying on this product for their safety could sustain severe personal injury or...
  • Page 4: Table Of Contents

    Table of Contents Chapter 1, General Information ....1-1 SafEye System General-Purpose Diagnostic Kit ..1-1 Figure 1-1. Case Contents ....1-1 Figure 1-2.
  • Page 5 Table 2-3. Detector’s Functions Setup ..2-9 Figure 2-8. Setup Screen .....2-9 Table 2-4.
  • Page 6: General Information

    Chapter 1, General Information This Diagnostic Kit manual is intended to supplement the SafEye Xenon 800 Open Path Gas Detection System Instruction Manual (P/N 10055711). The Diagnostic Kits allow the use of a convenient alternative to using a PC for installation, startup, and general diagnostic evaluation of the SafEye System.
  • Page 7: Figure 1-2. Pda Placement In Nylon Case

    1. Remove the nylon case and general-purpose PDA. 2. Remove the stylus pen from the PDA and place the pen into the pocket found on the side of the nylon case. 3. Place the general-purpose PDA in the nylon case as shown in FIGURE 1-2.
  • Page 8: Figure 1-4. Ir Module Tied Off To Nylon Case

    5. Close and button the flap, attach the shoulder strap, and refer to the user’s manual for operating instructions. 6. The wire from the IR module can be tied off to the nylon case as shown in FIGURE 1-4. Figure 1-4. IR Module Tied Off to Nylon Case 7.
  • Page 9: Safeye System Intrinsically-Safe Diagnostic Kit

    SafEye System Intrinsically-Safe Diagnostic Kit Figure 1-5. Case Contents (left to right, top to bottom): 1 shoulder strap 2 leather case 3 intrinsically safe PDA (preloaded with application software) 4 recharging plug 5 IR module • Not shown: instruction manual CD (only for reloading PDA software) 1.
  • Page 10: Figure 1-6. Pda Placement In Leather Case

    Figure 1-6. PDA Placement in Leather Case 3. Remove the IR module and place it in the leather case as shown in FIGURE 3. NOTE: The screw heads must face upward. Figure 1-7. IR Module Placement in Leather Case 4. Close and button the flap, attach the shoulder strap, and refer to the user’s manual for operating instructions.
  • Page 11: Figure 1-8. Ir Module Tied Off To Leather Case

    Figure 1-8. IR Module Tied Off to Leather Case 6. To recharge the intrinsically safe PDA, refer to the PDA user manual for instructions.
  • Page 12: Operation Instructions

    Chapter 2, Operation Instructions Running the Host Software 1. From the PDA Start screen, click on the START icon. 2. From the pop-up menu, click on the PROGRAMS option. 3. Click on the SAFEYE CONNECT icon. Opening Screen When the user starts running the host program: •...
  • Page 13: Main Screen

    Main Screen The Main screen: • monitors the detector • displays detector data (FIGURE 2-2). Detector Model Number Detector Status Detector Address Communication Status Detector Serial Number Detector Gain Figure 2-2. Main Screen Main Screen Pull-up Menu Buttons • The Main Menu screen pull-up lists are shown in FIGURES 2-3 and 2-4.
  • Page 14: Figure 2-3. Main Menu Screen Pull-Up Lists

    Figure 2-3. Main Menu Screen Pull-up Lists Figure 2-4. Main Menu Screen Pull-up Lists...
  • Page 15: Detector Status

    Table 2-1. Main Menu Pull-up Commands DEVICE MENU NAME DESCRIPTION Install Detector installation screens (signals information and zero calibration) Setup Detector options setup screen Master Press to retrieve detector address New Address Screen to set a new address S/N Test System diagnostic screen FILE MENU NAME...
  • Page 16: Installation Screens

    Installation Screens Once the SafEye System is physically aligned and the Main menu indicates "NNN" status, the user can verify installation using the Install function. Installation Results From the Device pull-up menu, click on the INSTALL button to access the Installation Result screen (FIGURE 2-5). •...
  • Page 17: Signals Information

    • The screen example shown in FIGURE 2-6 informs the user of a bad installation. Refer to the SafEye System Manual (P/N 10055711) for additional information. Figure 2-6. Error Message Signals Information Click on the SIGNALS INFORMATION button (via the Install function) to access the detailed system data and the electronic alignment (zero calibration) function.
  • Page 18: Figure 2-7. Signals Information Screen

    Detector address, status and gain Detector data channels (TABLE 2-3) ALIGN button - to align (zero) the detector* CLOSE button - to exit to the Main screen Communication status *The alignment (zero calibration) process: 1. Press the ALIGN button once and wait for status "XXX". 2.
  • Page 19: Channel Information

    Channel Information Table 2-2. Channels Description CHANNEL DESCRIPTION Voltage signal of reference, after electronic amplification Signal1 Voltage signal of sensor1, after electronic amplification (depends on gain) Signal2 Voltage signal of sensor2, after electronic amplification (depends on gain) Ratio1 Ratio between sensor1 and reference Ratio2 Ratio between sensor2 and reference NQRat1...
  • Page 20: Table 2-3. Detector's Functions Setup

    Detector parameters Detector Address (read only) SET OPTIONS button CANCEL button (to exit from Setup screen) Figure 2-8. Setup Screen Table 2-3. Detector’s Functions Setup NAME DESCRIPTION Gas Type Detector’s gas calibration definition (see TABLE 2-5) Full Scale Sens Full scale sensitivity options (see TABLE 2-6) BG Zero Calibration Zero calibration options (see TABLE 2-7) Accessory Relay...
  • Page 21: Table 2-5. Full Scale Sensitivity

    Table 2-4. Gas Type TYPE 100% Methane Natural Gas (92% Methane + 4% Propane + 4% Ethane) LPG (60% Propane + 40% Butane) not used not used not used not used not used Table 2-5. Full Scale Sensitivity HIGH Full scale sensitivity is 0 to 5 LEL.m (Default) Full scale sensitivity is 0 to 2 LEL.m Table 2-6.
  • Page 22 Table 2-8. 4 to 20 mA Mode CONTINUOUS DISCRETE Continuous reading of the 4 to 20 mA Discrete reading of the 4 to 20 mA output reading (Default) output reading according to the detector’s status Table 2-9. Beam Block During Alarm LATCH NO LATCH Alarm output indications are latched when...
  • Page 23: New Address Screen

    New Address Screen Click on the NEW ADDRESS button from the Main Menu Device Pull-up List (FIGURE 2-9). The New Address screen allows the user to set a new address for the detector. NOTE: The available addresses are from 1 to 247. Detector address to be set Keyboard digits to enter a new address CLEAR button to clear the Address screen...
  • Page 24: Signal/Noise Test

    Signal/Noise Test From the Device menu pull-up list, click on the S/N TEST button to access the Signal/Noise screen. • This screen offers diagnostic information and is to be used in conjunction with the Signals Information screen to ensure proper SafEye System operation.
  • Page 25: Detector Log File

    Detector Log File The PDA can record the detector’s parameters during operation [date, time, address, status, gain, LEL1 (gas reading), NQR1 (NQ ratio 1), NQR2 (NQ ratio 2)]. The user should first set the logging interval by pressing the LOG SETUP button (FIGURE 2-4).