Part Names and Functions
2
Switch two types of Base modes and their LEDs in the following way:
When Base mode is Status mode (factory default setting)
Boot
Status mode
(Base mode)
When Base mode is ECO mode
Boot
ECO mode
(Base mode)
※The Base mode is maintained even after the power is turned OFF.
LED lamps for each mode and LED lamps for ports 1 to 24 correspond as shown in Table 1 (see page 10).
●Loop detection/shutoff function and loop history function
Turns on the port LED with a orange light when a loop occurs in the
corresponding port. At this time, the relevant port automatically shuts down
(default setting: 60 sec.) to prevent loop from occurring.
If the loop is still not removed, the port will shut down again. Remove the loop
while the port is shut down.
During loop is occurring, or if loop has occurred within the latest 3 days, LOOP
HISTORY LED blinks to notify this.
It is possible to switch loop detection setting (OFF/ON) by using a console cable
(for detail, see the attached CD-ROM) or by pressing "LED DISPLAY CHANGE
BUTTON" for 10 seconds or more. (The default setting is ON.) When it is switched
successfully, LOOP HISTORY LED lights up and setting is complete.
If you wish to clear loop detection history, turn OFF once the power supply of the
Switching Hub and turn it ON again.
Then, loop detection history is deleted.
The Switching Hub can hold up to 64 loop history logs.
14
GIGA mode
Speed mode
Status
GIGA
mode
mode
Press "LED DISPLAY CHANGE BUTTON" manually.
Automatic
Automatically returns to Base mode after 1 minute.
DUPLEX
mode
Switch Base mode (keep pressing "LED DISPLAY
CHANGE BUTTON" over 3 seconds)
Press "LED DISPLAY CHANGE BUTTON" manually.
Automatic
Automatically returns to Base mode after 1 minute.
Speed
DUPLEX
mode
mode
Loop History
mode
Loop history
mode