3.0 WIRING AND CONNECTIONS

Before commencing wiring and connection work, read the SAFETY INSTRUCTIONS AND WARNINGS chapter carefully.
The operator must be connected to Life control units only.
OPERATORS
OP3 - OP3L - OP5 - OP5L
230 V
50 Hz
OP3 UNI - OP3L UNI - OP5 UNI - OP5L UNI
OP324 - OP524
24 V
OP324 UNI - OP524 UNI
All wiring and connection operations must be carried out with the control unit disconnected from the electricity supply. If the
disconnection device is not in view, display a sign reading: "ATTENTION: MAINTENANCE WORK IN PROGRESS".
The internal wiring of the linear electromechanical operator performed by the Manufacturer, may not be modified under any circumstances.
3.1 Electrical connections of the operator
One or two cables lead out of the operator depending on whether or not one has the UNI version.
The U
The 230 V and 24 V two-cabled versions have an extra cable for the encoder and limit switch signal (2-wired cable).
The 230V models come with a capacitor, which is housed in the control unit. The capacitor is connected in parallel to the "open motor" and "close
motor" cables.
OPERATORS
OP3 - OP3L - OP5 - OP5L
230 V
50 Hz
OP3 UNI - OP3L UNI - OP5
UNI - OP5L UNI
OP324 - OP524
24 V
OP324 UNI - OP524 UNI
N.B. each cable is 1m long.
OP3-OP3L-OP5-OP5L
C
D
F
E
OP3 24-OP5 24
G
H
I
GE1A 24
MOTOR POWER SUPPLY
BLUE/ GREY
BLACK
BROWN
YELLOW - GREEN
BLUE
BROWN
YELLOW - GREEN
A
B
A
B
5
INTEGRATED 433.92 MHz
LIFE PLUG-IN RADIO
RECEIVER
GE1A -GE2A
GE1A 24-GE2A 24
LIMIT SWITCH and ENCODER SIGNAL
COMMON
BROWN
OPEN MOTOR
BLUE
CLOSE MOTOR
EARTH
+
BROWN
-
BLUE
EARTH
OP3 UNI-OP3L UNI
OP5 UNI-OP5L UNI
OP324 UNI-OP524 UNI
RADIO RECEIVER
GE1R -GE2R
GE UNI R
GE UNI 24R
+
-
+
-
C
F
D
E
H
I
G