Step 9 Wiring The Fireplace - Heat & Glo GATEWAY Installer's Manual

Hide thumbs Also See for GATEWAY:
Table of Contents

Advertisement

BLOWER
VACUUM HOSE
CONNECTION POINT
ON/OFF
SWITCH
BLACK
ASSEMBLY
OPTIONAL
BLOWER
LEADS
Figure 3.27
Intermittent Pilot Ignition Wiring Diagram
Step 9. Wiring the Fireplace
NOTE: Electrical wiring must be installed by a licensed
electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF YOU
ARE ABSENT FOR EXTENDED TIME PERIODS. THIS
WILL PREVENT ACCIDENTAL FIREPLACE OPERATION.
For Intermittent Pilot Ignition Wiring System
Appliance Requirements
• This appliance REQUIRES 110-120 VAC to operate.
WARNING: DO NOT CONNECT 110-120 VAC
!
TO THE GAS CONTROL VALVE OR THE AP-
PLIANCE WILL MALFUNCTION AND THE VALVE
WILL BE DESTROYED.
• The gas control system used with this model is (IPI) Inter-
mittent Pilot Ignition. This system includes a 3 Volt control
valve, electronic module, and intermittent pilot.
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the factory installed junction box before
the fireplace is permanently installed.
HOT
NEUTRAL
TO REMOTE,
THERMOSTAT
OR WALL SWITCH
FAN
REM
120 VAC
JUNCTION BOX
Heat & Glo • Gateway • 288-900 Rev. S • 3/06
IGNITION
MODULE 3V
TRANSFORMER
3V
VACUUM HOSE
CONNECTION POINT
VACUUM SWITCH
BROWN
BROWN
Wall Switch
Position the wall switch in the desired position on a wall.
Using 14 GA or greater (following local codes) wire the
wall switch to the wire harness provided. The ground wire
must be securely attached to the ground stud in the junc-
tion box. Do not run 110-120 VAC to the valve. This valve
system runs off of the 3 Volt transformer (see Figure 3.25).
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.
WARNING: CONTINUOUS 110-120 VAC SER-
!
VICE MUST BE WIRED TO THE FIREPLACE
JUNCTION BOX.
SPARK TO
PILOT IGNITOR
ORANGE
I
(IGNITOR)
WHITE (SENSOR)
S
PILOT ASSEMBLY
AND VALVE
ASSEMBLY
MUST BE
BLACK
GROUNDED
(COMMON GROUND
WITH FIREPLACE
CHASSIS)
GROUND TO
FIREPLACE
CHASSIS
ORANGE
GREEN
25