  • Page 1 Gel Documentation <GP-07LED> FastGene ® FAS-Digi PRO Product GP-07LED Cat. No. Gel Documentation System Category Version 1.3 July/2019...
  • Page 2 Manual <GP-07LED>...
  • Page 3: Table Of Contents

    Manual <GP-07LED> Content General Information SAFETY INFORMATION REGULATORY NOTICE WARRANTY IMPORTANT NOTICE Specification CAMERA CONTROL DARKBOX ILLUMINATOR UNIT Nomenclature Installation guide – Setting up the FAS-Digi PRO ASSEMBLING THE CAMERA HOLDER CONNECTING THE CABLES CONNECTING THE CAMERA TO A PC Installation, Operation and Performance Qualification COMPUTER MINIMAL REQUIREMENTS INSTALLATION QUALIFICATION...
  • Page 4 Manual <GP-07LED>...
  • Page 5: General Information

    Nippon Genetics Europe is not responsible for any injury suffering from retina diseases. Therefore, we or damage caused by the use of this instrument for...
  • Page 6: Specification

    0.00025 to 30 seconds ® Filter FastGene amber filter attached by magnets Control Control Software NIPPON Genetics Camera Studio, Windows OS 10 or higher Saved Image Format TIFF, JPEG Image storage Host computer dependent Host computer dependent Interface Host computer dependent...
  • Page 7: Nomenclature

    Manual <GP-07LED> Nomenclature Blue/Green LED XL-Transilluminator • Darkbox • Amber goggles • ® FastGene amber filter shield attached with magnets (stored in the door) • Camera holder • USB-Stick with Software • Cables: • a. Battery adapter for the camera b.
  • Page 8 Manual <GP-07LED>...
  • Page 9 Manual <GP-07LED> Part I Installation...
  • Page 10: Installation Guide - Setting Up The Fas-Digi Pro

    Installation <GP-07LED> Installation guide – Setting up the FAS-Digi PRO Place the unit on a level surface with minimal chance of dropping. Assembling the camera holder The camera holder prevents the camera from turning when rotating the zoom ring using the aluminum adapter and is fixed by two screws to the darkbox and one tripod screw to the camera.
  • Page 11 Fix the camera holder on the camera using the tripod screw in the following order: Screw→Spacer→Camera holder→Spacer→Camera. Align the camera holder holes with the 2 small holes in the darkbox NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany...
  • Page 12 The darkbox connected with the camera is now ready and can be placed on top of the transilluminator. The next step will explain how to connect the cables. NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany...
  • Page 13: Connecting The Cables

    Add the power lead to the power socket and to the darkbox. Switch on the red switch on the back part of the darkbox. NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany...
  • Page 14: Connecting The Camera To A Pc

    The FAS-Digi PRO is powered up and can be used without a software. Here, we will explain how to connect the FAS-Digi PRO gel documentation system to a Windows 10 PC and to use the NIPPON Genetics Camera Studio software. Preparation: Check that the autofocus and the image stabilization are turned off.
  • Page 15 1. Start the NIPPON Genetics Camera Studio software: Please note if a blue SmartScreen appears: select More info and chose the option run anyway. This blue SmartScreen will only appear when the NIPPON Genetics Camera Studio is launched for the first time. NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0...
  • Page 16 Installation <GP-07LED> 2. Log in The NIPPON Genetics Camera Studio Software is password protected to avoid unauthorized people to have access to the gel documentation system. The password to enter the software 3. The software will open. You completed the installation of the FAS-Digi PRO. Please continue with the IQ/OQ/PQ protocol.
  • Page 17 Installation <GP-07LED> NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany info@nippongenetics.eu www.nipppongenetics.eu support@nippongenetics.eu...
  • Page 18 Installation <GP-07LED> NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany info@nippongenetics.eu www.nipppongenetics.eu support@nippongenetics.eu...
  • Page 19 Installation <GP-07LED> Part II IQ – OQ - PQ NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany info@nippongenetics.eu www.nipppongenetics.eu support@nippongenetics.eu...
  • Page 20: Installation, Operation And Performance Qualification

    FAS-Digi PRO GP-07LED Protocol Acceptance by Customer and List of Tests Performed NIPPON Genetics EUROPE recommends signing the IQ, OQ, PQ document when all tests are performed after installation. Operational Qualification should be run if the instrument is not performing to specifications. This document is used as the final QC-protocol of every unit we produce in Germany.
  • Page 21 • Blue/Green LED XL-Transilluminator • This document (Installation; IQ, OQ, PQ; Manual) • NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany info@nippongenetics.eu www.nipppongenetics.eu...
  • Page 22: Computer Minimal Requirements

    Check that no light is detectable (Black image) Examination Verification signature signature NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany info@nippongenetics.eu www.nipppongenetics.eu...
  • Page 23: Performance Qualification

    Activate exposure range and save one of the three pictures Examination Verification signature signature NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany info@nippongenetics.eu www.nipppongenetics.eu...
  • Page 24 IQ, OQ, PQ <GP-07LED> NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany info@nippongenetics.eu www.nipppongenetics.eu support@nippongenetics.eu...
  • Page 25 IQ, OQ, PQ <GP-07LED> Part III Manual NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany info@nippongenetics.eu www.nipppongenetics.eu support@nippongenetics.eu...
  • Page 26: Operating The System

    The password to enter the software is Main Menu The NIPPON Genetics Camera Studio Software can control all necessary parameters to take an image with the FAS-Digi PRO. All the following operations can be performed or accessed via the main menu: NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0...
  • Page 27: Selecting The Aperture

    Click on or use the mouse wheel on the screen to change the focal plane. NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany info@nippongenetics.eu...
  • Page 28: Change The Image Settings

    24 MPixel and is saved on the harddrive of the computer or on a network location chosen by the user. NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany...
  • Page 29: Excising Dna Bands

    DNA band using a scalpel or our FastGene ® Agarose Gel Band Cutter (FG-830) NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany info@nippongenetics.eu...
  • Page 30: Taking Images Using A White Light Source

    To add the filter to the lens, just hold the amber filter close to the lens and the magnet will pull the amber filter to the correct position. NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0 Fax: +49 (0) 2421 55 496 11 Binsfelder Straße 77 | 52351 Düren | Germany...
  • Page 31: Contact Details

    Manual <GP-07LED> Contact Details Please contact us for additional information: info@nippongenetics.eu Please contact our support: support@nippongenetics.eu NIPPON Genetics EUROPE GmbH Binsfelder Strasse 77 52351 Dueren Germany Fon: +49 2421 55 496 0 Fax: +49 2421 55 496 11 NIPPON Genetics EUROPE GmbH Tel.: +49 (0) 2421 55 496 0...