The surround consists of the following
parts (fi g. 2):
Part Description
1
Guide pin Ø6X25
2
Woodscrew Ø6x80 EZ
3
Hex Cap Screw DIN933-M8x16-8.8 Zinc Plated
4
Hex Flange Nut M6 DIN6923 8
5
Distance sleeve
6
Brakett front
7
Bracket left side middle uprofi le
8
Profi le side øvre uprofi l
9
Firewall FS 173
10
Bracket for height adjustment
11
Bracket right side middle uprofi le
12
screen plate part FS 173
13
Height adjustment screw M8x54
14
Bottom Plate
15
Lower Anchoring Profi le
16
Upper Anchoring Profi le
17
Upper Binding Profi le
18
Top Upper Anchoring Profi le
19
Top Front Anchoring Profi le
20
Bracket front uprofi le
21
Steel plate back low
22
Soapstone side upper R
23
Soapstone front up
24
Soapstone lower front
25
Soapstone side low left
26
Soapstone side lower right
27
Soapstone side middle L/R
28
Soapstone side upper L
29
Sector valve pl compl FS 173
30
Soapstone FS 173
31
Steel support for soapstone
35
Sector valve upper part
36
Sector valve lower part

3.0 Safety

NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are fi tted by a qualifi ed installer
(see www.jotul.com for a complete list of dealers).
Any modifi cations to the product may result in the product and
safety features not functioning as intended. The same applies to
the installation of accessories or optional extras not supplied by
Jøtul. This may also be the case if parts that are essential to the
functioning and safety of the fi replace have been disassembled
or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
12
3.1 Fire Prevention
Measures
Qty
8 stk
There is a certain element of danger every time you use
8 stk
your fi replace. The following instructions must therefore
24 stk
be followed:
4 stk
4 stk
The minimum safety distances when installing and using
1 stk
the fi replace are given in fi g. 1.
1 stk
Ensure that furniture and other fl ammable materials are not
2 stk
too close to the fi replace. Flammable materials should not
2 stk
be placed within 1 metre of the fi replace.
2 stk
Allow the fi re to burn out. Never extinguish the fl ames with
1 stk
water.
1 stk
The fi replace becomes hot when lit and may cause burns
1 stk
if touched.
1 stk
Only remove ash when the fireplace is cold. Ash can
1 stk
contain hot embers and should therefore be placed in a
1 stk
non-fl ammable container.
1 stk
Ash should be placed outdoors or be emptied in a place
1 stk
where it will not present a potential fi re hazard
1 stk
2 stk
3.2 Floor
2 stk
1 stk
2 stk
Foundation
2 stk
Make sure that the foundation is strong enough to bear the
1 stk
weight of the fi replace (110 kg + 274 kg).
1 stk
We recommend the removal of any fl ooring that is not attached
2 stk
to the foundation ("fl oating fl oors") beneath the installation.
1 stk
1 stk
1 stk
Requirements for protection of wooden
1 stk
fl ooring beneath the fi replace
1 stk
1 stk
The product has integrated fl oor protection and may therefore
be placed directly on a wooden fl oor.
Requirements for protection of
combustible fl oors in front of the
fi replace
The front plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
3.3 Walls
Distance to walls made of combustible materials - see fi g. 1.
The fi replace may be used with a semi-insulated fl ue pipe provided
the distances between the fi replace and walls made of combustible
materials are as shown in fi g. 1.
NB: Make sure that furniture and other household items are not
so close as to get dried up by the stove.

Advertisement

loading

This manual is also suitable for:

I 520