Hide thumbs Also See for N130:

Advertisement

Portable equipment
N130 / N330
QUICK GUIDE
BASIC
OPERATIONS
Rev. 01/2019 EN / Translation of the original instructions

Advertisement

Table of Contents
loading

Summary of Contents for CEMB N130

  • Page 1 Portable equipment N130 / N330 QUICK GUIDE BASIC OPERATIONS Rev. 01/2019 EN / Translation of the original instructions...
  • Page 2: Instruments Overview

    Connector 3: photocell input Connector 4: micro-USB port Connector 5: battery charger INCLUDED MEASUREMENT KIT Photocell with magnetic stand Accelerometer with magnetic base Accelerometer’s cable Photocell’s cable (2m length) (2m length) ACCELEROMETER SET PHOTOCELL SET (OPTIONAL FOR N130) Vibration analysis division...
  • Page 3: Connection Of The Cables

    N130/N330 KEYBOARD Switch ON/OFF the instrument Start/Stop of the measure Confirm the chosen setup/actions Function keys (refer to the display)
  • Page 4 Place the sensor on rigid parts of the machine (such as support bearings). All 3 orthogonal directions (X, Y and Z) are recommended. PHOTOCELL (Optional for N130) Put the reflecting tape on the shaft; place the photocell Point the photocell spot to the reflective tape on the machine casing using the magnetic stud.
  • Page 5 PHOTOCELL CALIBRATION (Optional for N130) With photocell power-on, touch the LED flashing Align sensor spot to the back of the body with a tool for 2 target. Faster flashing, better seconds reception Tap shortly, target thought Calibration successful Calibration failed...
  • Page 6: Instrument Setup

    Instrument setup INSTRUMENT MAIN SETUP FUNCTION Tap keys to choose the type of setup. to confirm and access to the function. SENSORS SETUP 1 - Define the type of sensor used (choice is between ACCELEROMETER and VELOMITOR). 2 - Define the sensitivity of sensor used for the measure. MEASURE SETUP Define all the parameters for the measure of the vibration.
  • Page 7: Device Setup

    DEVICE SETUP Define all the instrument parameters such as date, time, language, etc… NOTE: Tap “Arrows keys” to move inside the menu and make the choices. (DONE) to confirm the setup; tap (BACK) to leave the setup without any changes. www.cemb.it...
  • Page 8 How to take a measure From the MAIN MENU select the required measure function (this is applicable to VIBROMETER; FFT, CBA, TACHO). After to start-up the monitored rotating machine, tap to start the acquisition. When the reading is stable or when you want to shut down the acquisition, tap again In every function are available function keys HOME (A) - goes directly to the instrument home page, and MENU (B) - shows the menu of the function used.
  • Page 9 HOME to exit to the function. STEP No.2: CHOOSE THE FOUNDATION TYPE Tap keys to choose the foundation type. to confirm the selection. (BACK) to go back to machine type setup. www.cemb.it...
  • Page 10 Smart Analysis – Setup pages STEP No.3: CHOOSE THE SPEED DETECTION MODE Tap keys to choose the speed detection mode. to confirm the selection. (MACHINE SETUP) to go back to machine type setup (see step No.1). STEP No.4: MAKE A MEASURE While the machine is running, tap to start the acquisition.
  • Page 11 (BACK) to exit from the function. STEP No.2: CHOOSE THE NUMBER OF SUPPORT BEARING Choose the number of bearing starting from a default point. Tap keys to choose the support number. to confirm the selection. (BACK) to go back to list of existing projects. www.cemb.it...
  • Page 12 Tap keys to choose the orthogonal direction. to confirm the selection. (BACK) to go back to the previous step. For detailed information please refer to the N130/N330 user manual on the USB pen supplied with your instrument. Vibration analysis division...
  • Page 13 www.cemb.it...
  • Page 14 Vibration analysis division...
  • Page 15 www.cemb.it...
  • Page 16 CEMB S.p.A. - Via Risorgimento, 9 Vibration analysis division: 23826 Mandello del Lario (LC) - Italy Phone +39 0341 706111 www.cemb.com e-mail: stm@cemb.com...

This manual is also suitable for:

N330

Table of Contents