(N330 only) Connector 3: photocell input Connector 4: micro-USB port Connector 5: battery charger INCLUDED MEASUREMENT KIT Photocell with magnetic stand Accelerometer with magnetic base Accelerometer’s Photocell’s cable cable (2m length) (2m length) ACCELEROMETER SET PHOTOCELL SET (OPTIONAL FOR N130)
Page 3
N130/N330 KEYBOARD Switch ON/OFF the instrument Start/Stop of the measure Confirm the chosen setup/actions Function keys (refer to the display)
Page 4
Place the sensor on rigid parts of the machine (such as support bearings). All 3 orthogonal directions (X, Y and Z) are recommended. PHOTOCELL (Optional for N130) Put the reflecting tape on the shaft; place Point the photocell spot to the reflective tape previously positioned on the shaft.
Page 5
Sensors positioning PHOTOCELL CALIBRATION (Optional for N130) With photocell power- Align sensor spot to on, touch the back of the target. Faster LED flashing the body with a tool for flashing, better 2 seconds reception Tap shortly, target Calibration successful...
Instrument setup Instrument MAIN SETUP function Tap keys to choose the type of setup. to confirm and access to the function. SENSORS SETUP SENSORS SETUP Define the type of sensor used (choice is between ACCELEROMETER and VELOMITOR). Define the sensitivity of sensor used for the measure.
Instrument setup DEVICE SETUP DEVICE SETUP Define instrument parameters such as date, time, language, etc… NOTE: Tap “Arrows keys” to move inside the menu and make the choices. (DONE) to confirm the setup; tap (BACK) to leave the setup without any changes.
Page 8
How to take a measure From the MAIN MENU select the required measure function (this is applicable to VIBROMETER; FFT, CBA, TACHO). After to start-up the monitored rotating machine, tap to start the acquisition. When the reading is stable or when you want to shut down the acquisition, tap again every function are available...
Page 9
Smart Analysis – Setup pages STEP No.1: CHOOSE THE MACHINE TYPE As per ISO 10816-3 requirements, choose the correct machine type. Tap keys to choose the machine type. to confirm the selection. (HOME) to exit to the function. STEP No.2: CHOOSE THE FOUNDATION TYPE Tap keys to choose the foundation type.
Page 10
Smart Analysis – Setup pages STEP No.3: CHOOSE THE SPEED DETECTION MODE Tap keys to choose the speed detection mode. to confirm the selection. (MACHINE SETUP) to go back to machine type setup (see step No.1). STEP No.4: MAKE A MEASURE While the machine is running, tap to start the acquisition.
How to save a measure STEP No.1: CHOOSE OR CREATE A PROJECT (NEW) to create a new project. Or tap keys to scroll the existing projects. to confirm the selection. (BACK) to exit from the function. STEP No.2: CHOOSE THE NUMBER OF SUPPORT BEARING Choose the number of bearing starting from a default point.
Page 12
STEP No.3: CHOOSE THE ORTHOGONAL DIRECTION Tap keys to choose the orthogonal direction. to confirm the selection. (BACK) to go back to the previous step. For detailed information please refer to the N130/N330 user manual on the USB pen supplied with your instrument.