7. Lift the shroud up, tip the top of the shroud
toward the compressor, and pull the shroud
out of the machine compartment.
8.
9. Remove two 1/4 in. hex head screws to
remove the fan motor from the fan bracket
and shroud.

Condenser

The condenser is a steel coil which the
refrigerator uses to exchange heat from inside
the cabinet to outside the cabinet.
Condenser Removal
1. Follow Condenser Fan Removal, steps
1 through 7 (see Condenser Fan in this
section).
2. Follow recover procedure (see Evacuation
and Charging Procedure under the
Replacing Sealed System Components
section of this service guide), and disconnect
the inlet and outlet lines of the condenser.
3. Remove two 1/4 in. hex head screws.
NOTE: The condenser fan mounting bracket
connected to the bottom left of the condenser
coil will need to be reused when replacing the
condenser coil.

Compressor Electricals (TSD)

Compressor electricals (shown as TSD in the
schematic in this service guide) are made up of
an overload and relay combo and capacitor.
Compressor Electricals Removal
1. Remove the machine compartment cover.
2. Remove the retainer clip securing the combo
and capacitor to the compressor.
3. Pull the overload and relay combo and
4. Pull the capacitor and combo apart.
CAUTION: Compressor pin damage could result
– 36 –