15/04/09
For an immediate regeneration :
Push and hold the REGEN button for five seconds. The display will show the regeneration symbol.
The camshaft will start rotating to cycle C1.
En

OPTIONS

Logix Chlorine Generator (Check Salt Light)
The Logix 740C/742 and 760C/762 controls have the capability to produce a low level of chlorine
to chlorinate the resin bed during regeneration. Included with the chlorine generator is the check
salt light which indicates when the end user needs to add salt to the regenerant tank. Potassium chlo-
ride or sodium chloride may be used. Installing the chlorine generator is simple.
Installation instructions
STEP 1 - Remove the Logix control from the valve and dis-
connect power.
STEP 2 - Insert the small chlorine generator connector and
wire to the back of the Logix control at the connection labled
"Chlorine Generator Outlet 740C/742 and 760C/742". Logix
control removal procedure can be found in the Logix technical
manual.
STEP 3 - Remove the existing refill controler and ball from the
valve and replace it with the chlorine generator refill flow control.
See the illustrations to the left for the location of the refill controler.
STEP 4 - Insert the small chlorine generator connector and wire to the back of the Logix control
at the connection labled "Chlorine Generator Outlet 740C/742 and 760C/742". Logix control
removal procedure can be found in the Logix technical manual.
STEP 5 - Reconnect power to the logix control and reinstall the control to the valve
Refill controler
Check Salt Light
Injector and Cap
11:40
Page 16
For an immediate, double regeneration :
After an immediate manual regeneration has begun, and the
camshaft has rotated to cycle C1, you can initiate a second
immediate manual regeneration.
Press and hold the REGEN button for 5 seconds once the
camshaft has begun cycle C1.
The display will show a x2 icon indicating that a second
manual regeneration will occur after the current regeneration
is completed.
Programmation
No programming is necessary for the chlorine generator to
work properly on the 740C/760C. After the chlorine genera-
tor senses regenerant for the first time it will be functional.
There is a check salt light on the front of the Logix control
that will illuminate when there is no regenerant present during
the regenerant draw.
Chlorine Generator Outlet
(740C/742 and 760C/742 versions only)
16
Back on Logix Control