PROGRAMMING
AIRCOM T8 T9 T10

ALARM SETTING

In this mode, you can set what temperature the
system's alarm will trigger by pressing the up
and down triangle buttons. When the PROBE
temperature reaches or exceeds the ALARM
ALARM
temperature, the alarm will activate. The alarm will
only activate while the controller is in ON, AUTO, or
SMART Mode so please remember to exit ALARM
Mode once the alarm has been set.
When the alarm is triggered, the fan will run at
max speed regardless of mode and will make an
audible beep every three seconds. This will keep
occurring until the temperature drops below the
ALARM temp or if any buttons are pressed.
The alarm can be disabled to not trigger
by pressing the up triangle button until the
temperature is at 140° F, then pressing the up
button once more to show "OF".

FAHRENHEIT OR CELSIUS

The temperatures displayed can be set to Fahrenheit or Celsius scale by holding the LEAF button
until °F or °C is shown after the digits. All digits displayed will be automatically converted to the
designated scale.