Adexa KLG 150-S Operation Manual

Adexa KLG 150-S Operation Manual

Doner kebab grill with gas

Advertisement

Quick Links

Operation Manual
Doner Kebab Grill with Gas
Moving Body & Reversible Motor
KLG 150-S KLG 151-S KLG 152-S KLG 156-S
To avoid the risk of accidents or damage to the appliance it is essential to read these
operating instructions before it is installed or used for the first time.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KLG 150-S and is the answer not in the manual?

Questions and answers

Summary of Contents for Adexa KLG 150-S

  • Page 1 Doner Kebab Grill with Gas Moving Body & Reversible Motor KLG 150-S KLG 151-S KLG 152-S KLG 156-S To avoid the risk of accidents or damage to the appliance it is essential to read these operating instructions before it is installed or used for the first time.
  • Page 2: Table Of Contents

    List of Contents Presentation of Appliance ................... 3 KLG 150 .
  • Page 3: Presentation Of Appliance

    Presentation of Appliance / Präsentation des Gerätes DUK 4 Gas Doner Grill - 4 Burners / Döner Gasgrillgeräte 4 Brennern Bewegliches Gehäuse Moving Frame / Brenner Burners / / Ein/Aus Schaltknopf des Brenners Burners On / Off Knob / Brenner Abdeckung Burner Cover / Sicherheitsventil (Thermo Koppel) Termocouple...
  • Page 4: Klg 150

    Presentation of Appliance / Präsentation des Gerätes Appliance Name : Doner Kebab Grill with Gas (Moving Body & Reversible Motor) Name des Gerätes : Gasbetriebener Döner Grill (Bewegliches Gehäuse ) Model No : KLG 150 Other / Weitere Model Nr : KLG 150, KLG 151, KLG 152, KLG 156 Definition of the appliance The appliance consists of stainless steel frame, safety valve, moving body and lower reversible motor, working with gas (natural gas or LPG), and used for grilling foods such as Doner kebab meat wrapped around spits, etc.
  • Page 5: Safety Recommendations And Advices

    If you hesitate, please consult a qualified electrician. ➢ If the main cord is damaged, it must be replaced by ADEXA or an authorised technical service of ADEXA . ➢ Before gas connection of the appliance, check if local gas distribution requirements (type and pressure of the gas) and adjustment of the appliance are appropriate.
  • Page 6: Rules Of Operation

    Safety Recommendations and Advices ➢ Defective parts may only be replaced by original ADEXA spare parts. We as manufacturer may only assure you that you shall operate your appliance with these parts completely in safe. ➢ The manufacturing firm is not responsible for any damages that may be caused by improper mounting or connection of the appliance.
  • Page 7: Protection Against Burns

    ➢ All repair operations should be performed by Authorized Service Center. Any repairs to be performed by persons other than Authorized Service Centers may cause personal injury and appliance damage. Repairs should be performed by ADEXA Authorized Service Centre during warranty period. Otherwise, repair of troubles that may subsequently occur shall not be covered by the warranty.
  • Page 8: First Cleaning And First Heating

    Things to be done before First Operation Transportation and Storage ➢ If you need to transport the appliance, then move it in its original container and comply with the movement marks on the container. ➢ If the original container of the appliance is not available, fix the moving parts (Sword (or spits), fixing handle, Moving Body Frame and Oil Drawer) by using an adhesive tape.
  • Page 9 ➢ To turn the motor on, press " I " or " II " on knob of the switch. Rotation left or right direction could be set by these positions. ➢ To turn the motor off, bring knob to " 0 " position. Operation ➢...
  • Page 10: Verwendung

    Operation / Verwendung ➢ To operate heaters at low heat, turn “On-Off “ key (3.) until " " small flame mark shows “on” position. ➢ When Doner Kebab cooking is completed, turn “On-Off “ key (3. to “off ” position. ➢...
  • Page 11: Problemlösung

    Troubleshooting Problem Possible Cause Solution * Appliance does not * Inlet Valve connected to inlet of the * Open the Inlet Valve heat or burners appliance is closed. do not operate * Burner is out of order * Please contact our Customer Service * Burner Gas Supply Valve is out of order Team.
  • Page 12: Stromanschluss

    Technical Features / Technische Daten Electric Connection Stromanschluss FLEXIBLE CABLE (CORD) FELXIBLES KABEL NEUTRAL (BLUE) / NULLLEITER (Blau) LIVE (BROWN) / STROMLEITER (Braun ) PE : EARTH (GREEN AND YELLOW / ERDUNG (Grün und Gelb ) T echn ic a l Sp ec if ic a tion KLG 3 KLG 4 KLG 5...
  • Page 13: Austausch Der Drückdüse (Injektor)

    Technical Features / Technische Daten Injector Replacement ➢ Dismantle Radian Gas Supply Pipe-Valve Connection Sleeve (Figure 2). ➢ Pull and Remove Bushing Pin (Figure 3). ➢ Pull and Remove Gas Supply Pipe from radian gas inlet slot (Figure 4). ➢ Dismantle current injector, and insert a new injector appropriate to gas system intended to use instead of it (Figure 5). ➢...
  • Page 14 Technical Features / Technische Daten Electric circuit diagram / Elektrisches Kreislaufdiagramm...
  • Page 15 Seller Company (Stamp and Signature): GARANTIE Mit der Auflage, dass das Gerät wie in der Bedienungsanleitung von ADEXA genutzt wird und dass jegliche Reparaturen nur vom Kundenservice von ADEXA durchgeführt werden, beträgt die GARANTIEFRIST für Defekte, Verarbeitung und Zubehör 1 (EIN) JAHR.
  • Page 16: Customer Services

    Customer Services ➢ Service operation is performed at the plant facility. Service Center Address: ADEXA DIRECT LIMITED GROUND FLOOR, UNIT 1 JAYCEE HOUSE 214 PURLEY WAY. CROYDON, CRO 4XG.UK. M.+44 74 1107 0110 www.adexa.co.uk Firm Address: ADEXA DIRECT LIMITED GROUND FLOOR, UNIT 1 JAYCEE HOUSE 214 PURLEY WAY.