Troubleshooting guide
If you experience problems with the machine you can consult the troubleshooting guide or
contact us for service at Inkmachines.com
Symphtom
The motor
does not
start when the power is
on but the excenter
can be turned around
(normally) by hand. (
Electrical fault )
Possible cause
None or to low input
voltage.
Bad cable or power supply.
Bad connection.
Bad connection between the
and the
RCA contact
motor.
Short circuit between
and clipcord
housing
bindingpost positive ( + )
. The clipcord
bindingpost positive is
electrically isolated from
Possible Solution
Increase voltage (max 14 volts).
Make sure the power supply
delivers the right current. Consult
manual if necessary.
Check clipcord or RCA cable.
Replace if necessary.
Make sure the contactscrews are
not loose, tighten the following:
contactscrew motor negative ( - )
contactscrew bindingpost
negative ( - )
contactscrew cord positive ( + )
.
Loosen the RCA nut
unscrew the RCA contact
Remove possible oxide by sanding
the tip of the contact that engages
with the contact plate of the motor.
Clean the contact plate (visible
trough the threaded hole) with
alcohol on a cotton bud. Turn the
RCA contact until the tip touches
the contact plate gently. Tighten
the nut gently.
Remove the clipcord bindingpost
and the sleeve.
positive ( + )
Replace if necessary.
and
.
5