Download Print this page

Blue Wave FlowXtreme Pro Series Manual page 9

Advertisement

R. Trouble Shooting
Malfunction
Cause
Pressure gauge
Dirty filter bed
has
reading
more
than
10
PSI
over
the
normal
filtering
pressure
Pressure is too
Hair and lint strainer basket
low
is dirty; Pump gets too little
water
Air in the pump
Poor seal on the intake side
of pump
Leaking filter
Seal Defective
Pump does not
Not plugged in
run
G.F.C.I./
breaker tripped
Pump motor defective
Sand in Pool
If
replaced,
grains are still present
Sand in Central Valve (from
backwash)
Filter bottom
laterals are damaged
Air in system
or
main
circuit
the
sand
is
newly
the
undersized
strainer or
Page 09
Solution
Backwash the filter (position 4)
Clean the hair and lint strainer;
check the suction line and the
water level
Tighten
hose
clamps
connecting fittings
Check the seal, replace if needed
Check the socket and power cord
Switch on the breaker (if it is
immediately tripped again, there is
a defect in pump or controls)
Replace motor or entire pump
Backwash several times until the
backwash water is clear (position
4)
Purge
into
drainpipe
seconds (position 6)
Replace the filter bottom strainer
Loosen, but do not re-move, the
air
relief
valve
plug
multi-position valve to allow any
trapped air to escape. Tighten the
valve plug once all of the air has
escaped.
and
for
30
on
the

Advertisement

loading
Need help?

Need help?

Do you have a question about the FlowXtreme Pro Series and is the answer not in the manual?

This manual is also suitable for:

Flowxtreme pro ne4490Flowxtreme pro ne4499