Serp Gng; Calibration; Flashing The Test Program (Itp) Into The Mobile - Sony Ericsson K530i Test Instructions

Table of Contents

Advertisement

3.2.3

SERP GNG

NOTE!
1. On a PC with SERP installed, start the SERP program by double clicking on the
"RepairManager.exe" icon on the desktop.
2. Click on "Settings" in the SERP Window and verify that the test instrument and
the GPIB address correspond.
3. Click on the "Station Setup" tab and verify that the "cable" (or the coupler)
settings are selected under the "RF Connection-GoNogo" Drop down window.
Click on "Apply" and then the "OK" button.
4. Enter (or scan) the IMEI number of the mobile to be tested into the "Enter IMEI"
box in the SERP Window and click on the "Load" button. The appropriate phone
model will be displayed.
5. In the SERP window, check the "Final GoNogo Test" box only. Click on the
"Start Test" button and follow the instructions. (Power on the phone when the
"Call Connection" dialog box appears.)

4 Calibration

NOTE!
4.1

Flashing the Test Program (ITP) into the Mobile

NOTE!
Flash the Test Program software into the mobile by doing the following:
1. Attach a fully charged battery to the mobile.
2. Open the EMMA III application and log in.
3. Ensure the mobile is powered off.
4. While holding the "C" button, connect the mobile to the USB Flash cable. (Once
the USB symbol appears in the lower left corner of the EMMA III window you may
release the "C" button.)
5. Select the "V640/K630 ITP protocol and follow the on screen instructions.
NOTE!
2/000 21-2/FEA 209 544/136 C
©
Company Internal
Sony Ericsson Mobile Communications AB
For complete and detailed user instructions, see the SERP Users
Manual located in the SERPINFO.htm that gets placed on the Desktop
after SERP is installed.
A Test Program must be loaded in the handset before performing the
calibration routine. After calibration the handsets must be re-customized
with signalling SW.
Flashing instructions may vary depending on the interface used.
Under most circumstances the display on the mobile will be blank when
the Test Program is installed.
Test Instruction, Electrical