INFINITY controllers

Water controllers are an optional extra. They allow precise temperature control—no need to mix
hot and cold water.
General controller information
When used correctly the Rinnai INFINITY, when
combined with digital controllers will deliver the
selected temperature at the controller, even
when the water flow varies, or when more than
one tap is in use.
Each digital water controller can be individually
programmed, though the INFINITY can
only deliver one set temperature at a time.
For example, someone is showering at a
temperature of 43 °C, and another person uses
the kitchen tap. The kitchen tap can only deliver
43 °C until the person in the shower is finished.
Available Rinnai controllers
Compact, temperature selection only
Kitchen Deluxe, temperature selection and
voice prompting
Bathroom Deluxe, temperature selection,
shower saver, bath fill, and voice prompting
Controller configurations
A maximum of four (three for the N-Series)
water controllers can be fitted, with the
following provisos:
Only one Kitchen Deluxe controller can be
fitted. A Kitchen Deluxe is only installed if a
Bathroom Deluxe controller is installed.
Only two Bathroom deluxe controllers can
be fitted.
Only one controller can be set to deliver
55 °C, this cannot be the controller in the
bathroom.
Controllers need to be turned on
The Rinnai INFINITY will not heat the water
unless the controller(s) are turned on. If water
is flowing before a controller is turned on, the
Rinnai INFINITY will not heat the water. Turn off
the tap for a few seconds then turn on again.
Ignition problems
If the Rinnai INFINITY fails to ignite the 'In
Use' indicator will not illuminate. The Rinnai
INFINITY will not attempt re-ignition until the
water flow is stopped for a few seconds and
then restarted.
When gas bottles have been changed or the
gas supply is disrupted (controller may display
error code 11 or 12) ignition may fail and the 'In
Use' indicator won't be on. The water flow may
need to be stopped and restarted several times
before the appliance will operate.
Available temperatures on controllers (°C)
Kitchen (domestic)
Kitchen (commercial)
Bathroom (hot water)
Bathroom (bathfill)
For water temperatures lower than 37 °C, add
cold water.
Rinnai INFINITY operation guide 02-20 | 7