Chapter 3 — About the Scanner
Data Processing Settings (continued)
Setting
Prefix
Suffix
Wedge as Keys
Data Editing Plugin
Symbology Prefix
Launch Browser
40
Description
Defines the string added before the decoded bar code
data. Substitutions occur within the Prefix string values
as follows:
• \r is replaced by 13
• \n is replaced by 10
• \t is replaced by 9
• \\ is replaced by '\'
Defines the string added after the decoded bar code
data. Substitutions occur within the Suffix string values
as follows:
• \r is replaced by 13
• \n is replaced by 10
• \t is replaced by 9
• \\ is replaced by '\'
List of character values to wedge as keys, represented
as a comma-separated list of decimal values.
Specify a Total Freedom data editing plug-in.
Specify a symbology identifier prefix to the bar code
data. Options include:
• None
• Honeywell
• AIM
Enable or disable URL bar code handling. If a bar code
starts with http:// or https://, the browser opens using the
bar code data as a URL.
Corresponds to BarcodeReader property:
PROPERTY_DATA_PROCESSOR_LAUNCH-
BROWSER
Default
None
None
9,10
None
None
Enable