DOM ENIQ Guardian Manual

Hide thumbs Also See for ENIQ Guardian:

Advertisement

-Guardian & Guardian S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ENIQ Guardian and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DOM ENIQ Guardian

  • Page 1 -Guardian & Guardian S...
  • Page 2: Table Of Contents

    CONTENTS SCOPE OF SUPPLY PRODUCT DESCRIPTION FOR YOUR OWN SAFETY IMPORTANT INFORMATION REQUIRED TOOLS DOOR PREPARATION Drilled holes for Guardian and Guardian S for installation of outer fitting and inner fitting on both sides Drilled holes for Guardian outer fitting or inner fitting, one-sided installation INSTALLATION Installation of Guardian...
  • Page 3: Scope Of Supply

    SCOPE OF SUPPLY Depending on the order: GUARDIAN 1) 2x screws M6 2) 1x screw M5 3) Cover and base plate on the inside with long inner handle and threaded pin 4) Square 5) Sleeve if required 6) Base plate with threaded sleeves, slide, coupling module, U-profile with electronics fitted and outer cover 7) Short inner handle with threaded pin...
  • Page 4 GUARDIAN OUTER FITTING 1) Square 2) Sleeve 3) Base plate with threaded sleeves, slide, coupling module, U-profile with electronics fitted and outer cover 4) Short inner handle with threaded pin 5) Battery 6) Battery compartment 7) 4x wood or countersunk screws M5 8) 2x screws for battery compartment Fig.
  • Page 5: Product Description

    PRODUCT DESCRIPTION All DOM access control components and thus also the Guardian leave the factory in a neutral state. They are only “initialised” i.e. assigned to a master card shortly before installation. From this moment onwards, programming can only be performed on the terminal device from this master card or from a programming card authorised with this master card.
  • Page 6: Important Information

    IMPORTANT INFORMATION Caution! Locking media do not belong in the hands of small children. Small parts may be swallowed. Caution! Material damage due to improper storage. If you store the Guardian for an extended period prior to installation, store all the components in their original packaging in a dry, dust-free location at room temperature (see also chapter Storage/Care).
  • Page 7: Required Tools

    REQUIRED TOOLS For proper installation, the following tools are required: (not included in the scope of supply) Ruler or suitable measuring instrument Hexagon socket key (Allen key): 2 mm, 3 mm. Slot-head screwdriver Pointed pliers Guardian drilling template (recommended, optionally available) Depending on the installation method: Guardian: Torx screwdriver (Torx T25)
  • Page 8: Door Preparation

    The door must be prepared in compliance with the fitting centre distances. Caution! We recommend use of the Guardian drilling template which you can purchase through DOM Sicherheitstechnik. (see 17) Caution! The Guardian can be screwed on doors with a thickness from 34 mm to 114 mm and a distance between handle and cylinder from 55 mm to 94 mm (see Technical data).
  • Page 9: Drilled Holes For Guardian Outer Fitting Or Inner Fitting, One-Sided Installation

    DRILLED HOLES FOR GUARDIAN OUTER FITTING OR INNER FITTING, ONE-SIDED INSTALLATION Inner Outer Hole spacing outer fitting: 82 mm from the handle hole upwards (two holes at the top) 118 mm from the handle hole downwards (two holes at the bottom) 20 mm space vertically between the two holes Hole spacing inner fitting: 75.5 mm top...
  • Page 10: Installation

    INSTALLATION Proceed according to the sequence described and observe the notes and figures. Caution! If you have ordered a special version of the Guardian or Guardian S, read through the suitable sections in the Special versions chapter first (see 17) before you continue. Caution! Before the Guardian is installed, you must check to ensure the lock is working properly.
  • Page 11: Installation Of Guardian

    INSTALLATION OF GUARDIAN Follow the steps below: Please note! Always pay attention to the position of the set screw for fastening the square. It must be located on the top side (12 o‘clock position) of the coupling module. 1. Insert the square, with adapter sleeve if appropriate, into the coupling module: make sure you align the eccentric drilled hole on the square to the threaded pin / set screw of the inner handle.
  • Page 12 6. Set the (short) outer handle onto the square, without clicking the handle into the easyfix attachment. 7. Present the authorised transponder. 8. Check smooth movement and coupling function. 9. If everything is working properly, click the handle into place, but do not secure it with the threaded pin yet. Fig.
  • Page 13: Installation Of Guardian S

    INSTALLATION OF GUARDIAN S Follow the steps below: Please note! It is urgent that you pay attention to the position of the threaded pin / set screw for fastening the square. It must be located on the top side (12 o‘clock position) of the coupling module.
  • Page 14: Installation Of Guardian Outer Fitting

    5. Place the inner fitting onto the door leaf and fix it in place with the 3 screws. Please note! The longer of the three screws is inserted into the lowest hole and fixes the battery compartment in addition. To do this, push the battery compartment into the outer fitting and hold it tight.
  • Page 15 3. Remove the battery compartment and battery as described in the Battery replacement chapter. (see 32, steps 1 to 4) 4. Use a Torx spanner (Torx T10) to loosen the cover and lift it slightly. 5. Clip the cover out at the top of the U-profile. Fig.
  • Page 16 9. Clip the cover in at the top of the U-profile. 10. Hook the tab on the outer cover in between the screw and the U-profile and press into place. 11. Secure the cover using the attachment screw and tighten using the Torx spanner (Torx T10). 12.
  • Page 17: Installation Of Guardian Inner Fitting

    INSTALLATION OF GUARDIAN INNER FITTING Follow the steps below: 1. Set the handle onto the square. 2. Hold the cover horizontally so that the screwing points are visible. 3. Tighten the screws. 4. Check function. 5. Snap the cover into place. 6.
  • Page 18 DRILLED HOLES FOR GUARDIAN AND GUARDIAN S: For installation on both sides, you must use the three inner drilled holes. A through hole must be drilled. Drilling diameter top/bottom = 10 mm Drilling diameter centre = 8 mm With the Guardian S all three drilled holes must have been spot-drilled to 10 mm depth first using a 16 mm drill.
  • Page 19: Renovation Plate

    DRILLED HOLES FOR GUARDIAN INNER FITTING For installation on both sides, you must use the three inner drilled holes. A through hole must be drilled. Drilling diameter top/bottom = 10 mm Drilling diameter centre = 8 mm Recommendation: always drill on both sides to ensure the exact positioning of the fittings.
  • Page 20: Symmetrical Handle Lock

    SYMMETRICAL HANDLE LOCK Depending on the use of the handle lock, you can limit or permit the upward operation angle of the handle. Caution! Upon delivery, the handle lock is inserted in the module setting neutral (N). Please note! Depending on the direction the handles are facing, you will have to align the handle lock in different ways.
  • Page 21 3. Turn the handle lock and insert the handle lock in accordance with your installation situation: R: module setting right: the door hinges (A) are on the right-hand side. Fig. 29: Module setting right N: module setting neutral: The handle can be moved 45° up and down. Fig.
  • Page 22: Asymmetrical Handle Lock

    ASYMMETRICAL HANDLE LOCK The asymmetrical handle lock can be fitted in additional to the angle restriction for adjustment purposes if the handle is not in a horizontal position. As a rule the asymmetrical handle lock can be installed in Guardian versions which are fitted with a grey coupling module. Please note! Remove the unit in accordance with the installation instructions.
  • Page 23 L: The door hinges are located on the left-hand side: 4. Rotate the asymmetrical handle lock so that the arrow is pointing upwards and insert the handle lock in accordance with your installation situation. Fig. 34: Left-hand door hinges Caution! After you have inserted the asymme- trical handle lock close the slide again.
  • Page 24: Putting Into Operation

    Please note! The Guardian automatically detects transponders which approach the reading field. In rare cases, environmental factors in the form of interference fields or the use of transponders not approved by DOM Sicherheitstechnik may result in the failure of the DOM ENiQ cylinder to detect transpon- ders automatically.
  • Page 25: Operation

    OPERATION Now you can use the master card to create programming cards which you can use in turn to create locking media. Please note! The master and programming cards do not function as locking media. Master card The master card has the following functions: •...
  • Page 26: Opening

    OPENING To open the door, all you have to do is hold an authorised locking media a short distance in front of the reading module. Authorised transponder: The Guardian engages and the green LED flashes during the set coupling duration. Once the coupling duration has expired, the red LED flashes once.
  • Page 27: Creating Locking Or Programming Media

    CREATING LOCKING OR PROGRAMMING MEDIA You need the master or programming card and the media that you wish to create. Please note! You can create a maximum of 5 programming cards. Once you have created a programming card, you can also continue the further programming with the programming card. Follow the steps below: 10.
  • Page 28: Deleting Locking Or Programming Media

    DELETING LOCKING OR PROGRAMMING MEDIA You need a master or programming card and the media that you wish to delete. Follow the steps below: 12. Hold the master or programming card flat a short distance in front of the reading module twice in quick succession: presentation of the card is confirmed by two green flashes.
  • Page 29: Deleting All Locking Or Programming Media

    DELETING ALL LOCKING OR PROGRAMMING MEDIA If you have lost a locking media, you can no longer individually delete this locking media (without software or Easy Flex system). In this case, you must delete all locking media and create the existing locking media again. You only need a programming card to do this.
  • Page 30: Programming And Management With Software

    Please note! Perfect communication between the PC/laptop and Guardian is only guaranteed when the infrared adapter recommended by DOM is used. You can find information about this in the operating manual of the ELS® software or directly from DOM Sicherheitstechnik.
  • Page 31: Maintenance

    Please note! External light (e.g. fluorescent lamps) can interfere with the infrared connection. Please note! Soiling of the infrared module and/or the reading module can interfere with a perfect infrared connection. MAINTENANCE The Guardian is maintenance-free. Power is supplied to the Guardian by a 3.0 V lithium battery pack. A low battery warning indicates that the battery pack must be changed.
  • Page 32: Battery Replacement

    (e.g. water pipe, heating) beforehand to remove electro- static charge from your body. Please note! Only use the 3.0 volt lithium batteries from DOM Sicherheitstechnik which are already pre-assembled with the connection cable.
  • Page 33: Guardian S Battery Replacement

    (e.g. water pipe, heating) beforehand to remove electro- static charge from your body. Please note! Only use the 3.0 volt lithium 2-CR2 pack (battery) from DOM Sicherheitstechnik which are already pre-assembled with the connection cable.
  • Page 34 1. Undo the lower screw on the inside and screw it out around 15 mm: you can now remove the battery compartment on the outside. 2. Remove the old battery from the battery compartment. 3. Carefully disconnect the connection cable. 4.
  • Page 35: Removal

    REMOVAL Depending on the installation situation (both sides, one side), the removal procedure differs. Caution! Avoid electrostatic charges prior to the removal of electronic components or touch a conductive, grounded object (e.g. water pipe, heating) beforehand to remove electrostatic charge from your body. Never touch the electronics components with your fingers.
  • Page 36: Removal Of The Guardian Outer Fitting

    Removal of the Guardian outer fitting Caution! If the Guardian is fitted on one side, you may not loosen the hexagon socket screw on the handle until directly before you remove the coupling module from the U-profile. Otherwise the electrical supply lines to the coupling module can become damaged.
  • Page 37: Removal Of The Guardian Inner Fitting

    Removal of the Guardian handle Please note! To loosen the easyfix attachment you must use pliers to unlock the quick fastening. We recommend the handle removal tool from DOM for this. Press both wings of the easyfix attachment (lower ring) apart using the removal tool and exert gentle pressure to pull the handle out of the mount at the same time.
  • Page 38: Storage/Care

    Please note! You can find the current technical data sheets on the website of DOM Sicherheitstechnik GmbH. WARRANTY See the general terms and conditions (T&C) from DOM or the general terms and conditions of your specialist retailer from whom you purchased the product for the warranty regulations.
  • Page 39 DOM-Sicherheitstechnik GmbH & Co. KG, 50301 Brühl This documentation must not be reproduced either in whole or in part, stored, transmitted or translated in any form or using any media without the prior written consent of DOM Sicherheitstechnik GmbH & Co. KG. Important note This documentation is updated at regular intervals.