Safety Precautions The following are general safety precautions that are not necessarily related to any specific part or procedure, and do not necessarily appear elsewhere in this publication. These precautions must be thoroughly understood and apply to all phases of operation and maintenance. WARNING Keep Away From Live Circuits Operating Personnel must at all times observe general safety precautions.
Safety Precautions Safety Symbols WARNING Warning notes call attention to a procedure which, if not correctly performed, could result in personal injury. CAUTION Caution notes call attention to a procedure which, if not correctly performed, could result in damage to the instrument. The caution symbol appears on the equipment indicating there is important information in the instruction manual regarding that particular area.
Termaline® Coaxial Load Resistor Caution Statements The following cautions appear in the text whenever the equipment is in danger of damage, and are repeated here for emphasis. CAUTION The load is designed for operation in a horizontal plane only, with mounting brackets down.
Safety Precautions Safety Statements USAGE ANY USE OF THIS INSTRUMENT IN A MANNER NOT SPECIFIED BY THE MANUFACTURER MAY IMPAIR THE INSTRUMENT’S SAFETY PROTECTION. EL USO DE ESTE INSTRUMENTO DE MANERA NO ESPECIFICADA POR EL FABRICANTE, PUEDE ANULAR LA PROTECCIÓN DE SEGURIDAD DEL INSTRUMENTO.
Page 6
Termaline® Coaxial Load Resistor SERVICE SERVICING INSTRUCTIONS ARE FOR USE BY SERVICE - TRAINED PERSONNEL ONLY. TO AVOID DANGEROUS ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING UNLESS QUALIFIED TO DO SO. SERVICIO LAS INSTRUCCIONES DE SERVICIO SON PARA USO EXCLUSIVO DEL PERSONAL DE SERVICIO CAPACITADO.
About This Manual About This Manual This instruction book covers the Models 8201 and 8203 Termaline Load Resistors. Changes To The Manual We have made every effort to ensure this manual is accurate at the time of publication. If you should discover any errors or if you have suggestions for improving this manual, please send your comment to our factory.
Chapter 1 Introduction This publication refers to the Termaline Load Resistor models 8201 and 8203. The differences between the models are listed in the specifications. Both models will generally be referred to as a load throughout this manual. Purpose and Function These loads are portable, general purpose 50 ohm coaxial transmission line terminations.
Introduction The Model 8203 Termaline Load Resistor will take a load of up to 600 W, over a frequency range of DC to 1000 MHz. Its maximum VSWR rating is 1.1 to 1.0 over this frequency range. Note: The specifications for the Model 8203 apply only as long as the ambient temperature remains at 30°C (+86°F) or lower.
Termaline® Coaxial Load Resistor Items Required Only a coaxial cable with the appropriate connector plug (normally a Male N or, with the Model 8203, a Female N), is needed for connecting these load resistors to the source of RF power. Tools and Test Equipment ...
Chapter 2 Theory of Operation The Models 8201 and 8203 Termaline Load Resistor consist essentially of a carbon film-on-ceramic resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special exponentially tapered housing. This provides a linear reduction in surge impedance directly proportional to the distance along the resistor.
Chapter 3 Installation Location CAUTION The load is designed for operation in a horizontal plane only, with mounting brackets down. Do not operate in any other position. Install the Model 8201 or 8203 Termaline Load Resistor in a location that: ...
Chapter 4 Operating Instructions Use and Function of Controls Because these are passive devices, there are no operating controls on the Models 8201 and 8203 Load Resistors. Initial Adjustments No initial adjustments are required other than to connect the load to the RF source by means of a coaxial cable equipped with a suitable matching connector plug.
Termaline® Coaxial Load Resistor Operating Under Emergency, Adverse, or Abnormal Conditions CAUTION Do not operate this equipment continuously above the rated 500 W for Model 8201, or 600 W for Model 8203. Load failure will result. Shutdown Because both the Models 8201 and 8203 are passive devices, there is no way to turn them off.
Chapter 5 Maintenance This chapter contains operator maintenance instructions, troubleshooting, and parts information. Troubleshooting Problem Possible Cause Remedy Tighten clamping band with Clamping band not tight. a screwdriver. Leakage of coolant oil Replace per the RF Load around band or radiator Faulty o-ring (front).
Termaline® Coaxial Load Resistor Inspection With the rugged and simple construction of the Models 8201 and 8203 Load Resistors, periodic inspection will be necessary at only about six-month intervals. Inspection should include the items listed below: 1. Oil Leakage - Check for coolant oil seepage around the radiator tank, particularly at the front and back around the underside of the clamping band.
Maintenance Disassembly There are no special techniques required for the repair or replacement of components in the Models 8201 and 8203 loads. A screwdriver is the only tool needed. RF Connector Replacement The connector is a patented “Quick Change” design which permits easy interchange with the use of only a screwdriver.
Termaline® Coaxial Load Resistor Assembly RF Connector Before pushing the RF connector in, be sure that the projecting center contact pin on the connector is carefully engaged and properly seated in the mating socket of the load resistor input. Install the four 8-32 x 5/16 inch round head machine screws into the corners of the RF connector.
If the unit needs to be returned for any reason, request an Return Material Authorization (RMA) through the Bird Technologies website. All instruments returned must be shipped prepaid and to the attention of the RMA number.
Termaline® Coaxial Load Resistor Specifications Impedance, Nominal 50 ohms VSWR, Max Model 8201: 1000-2500MHz 1.1:1.0 Model 8203: DC-1000MHz 1.25:1.0 Connectors Female N “QC” type normally supplied Power Range Model 8201 500 W Continuous Model 8203 600 W Continuous Frequency Range Model 8201 DC - 2500 MHz Model 8203...
Limited Warranty All products manufactured by Seller are warranted to be free from defects in material and workmanship for a period of one (1) year, unless otherwise specified, from date of shipment and to conform to applicable specifications, drawings, blueprints and/or samples. Seller’s sole obligation under these warranties shall be to issue credit, repair or replace any item or part thereof which is proved to be other than as warranted;...