PROBLEM
Softener fails to
1
regenerate
Softener delivers
2
hard water
Unit uses too
3
much salt
Loss of Water
4
Pressure
Fleck Model 5600 & 5600 Econominder
Trouble-Shooting Guide
CAUSE
A) Electrical service to unit has
been interrupted.
B) Timer is defective.
C) Power failure occurred.
A) By-pass valve is open.
B) No salt in brine tank.
C) Injectors or screen plugged.
D) Insufficient water flowing into
brine tank.
E) Hot water tank hardness.
F) Leak at distributor tube.
G) Internal valve leak.
H) Reserve capacity has been
exceeded.
I) Program wheel is not rotating with
meter output.
J) Meter is not measuring flow.
A) Improper salt setting.
B) Excess water in brine tank.
A) Iron buildup in line to water
conditioner
B) Iron buildup in water conditioner
C) Inlet of control plugged due to foreign
material broken loose from pipes by
recent work done on plumbing
system.
CORRECTION
A) Assure permanent electrical service
(check fuse, plug, pull chain or switch)
B) Replace timer motor.
C) Reset time of day
A) Close by-pass valve.
B) Add salt to brine tank and maintain
salt level above water level.
C) Replace injectors and screen.
D) Check brine tank fill time and clean
brine line flow control if plugged.
E) Repeated flushings of the hot water
tank is required.
F) Make sure distributor tube is not cracked.
Check O-ring and tube pilot.
G) Replace seals and spacers and/or piston.
H) Check salt dosage requirements and reset
program wheel to provide additional reserve.
I) Pull cable out of meter cover and rotate manually.
Program wheel must move without binding and
clutch must give positive "clicks" when program
wheel strikes regeneration stop. If it does not,
replace timer valve head.
J) Check output by observing rotation of small gear
on front of timer with water running in house (Note:
program wheel must NOT be against regeneration
stop (0) for this check.) Each tooth to tooth is
approximately 30 gals. If not performing properly,
replace meter cover (dome).
A) Check salt usage and salt setting.
B) See problem #7
A) Clean line to water conditioner
B) Clean control and add resin cleaner to resin bed.
Increase frequency of regeneration.
C) Remove piston and clean control.

Advertisement

loading

Summary of Contents for Pentair Fleck Econominder 5600

  • Page 1 Ponds & Water Features • Swimming Pools & Spas • Well Water Sytems • Water Treatment • Wastewater • Rainwater Harvesting Fleck Model 5600 & 5600 Econominder Trouble-Shooting Guide PROBLEM CAUSE CORRECTION A) Assure permanent electrical service A) Electrical service to unit has Softener fails to (check fuse, plug, pull chain or switch) been interrupted.