9. RECORDING EQUIPMENT CONNECTION

Connect the recorder's recording input terminal to the Central unit's recording output terminal. If the recorder
has its recording level control, adjust it to an appropriate recording level.
Tip: For operation of the recorder, refer to the instruction manual included with the recorder.
Central unit TS-920RC
(Rear panel)

10. CONFERENCE UNIT INSTALLATION AND SETTINGS

Step 1. Use a screwdriver to set the Unit address number setting switch
located on the unit's bottom side.
Set a numeral for the ones place and tens place.
As for the hundreds place, shift this switch to OFF for a numeral
"0" and to ON for "1."
Set the unit address number (001 – 192), taking care to ensure
that the same number is not duplicated in the system.
If the number [000] is assigned to a unit, the user of that unit
cannot speak. However, the unit can be used for monitoring.
Note
This number is factory-preset to [000].
Step 2. Mount the microphone to the Conference unit.
34
Recorder
Microphone (standard) TS-923
Recording output (REC OUT, monaural)
Tip
Connection when a RCA plug cable is used.
or
Microphone (long) TS-924
The figure shows the TS-921.
Conference unit
(bottom side)
ON
(Inside of the cover)
Ones digit
Tens digit
Hundreds digit
The figure shows the TS-921.